摘要
A flow-batch hybrid system is proposed as a novel approach to automated titration. Sampling and signal processing are done as in usual flow systems, whereas chemical reactions take place in a reaction chamber similar to those found in batch systems. End point is found by means of the Fibonacci method, adapted to act as a one-dimensional optimisation algorithm for fast titration. A model system involving the spectrophotometric NaOH/HCl titration was initially studied, and the feasibility of the approach was further demonstrated in the titration of white wines with NaOH using m-cresol purple as indicator. About 20 samples are run per hour and ca. 0.6 ml of sample and titrant are consumed per determination. Within the 5.2-7.3 g l(-1) acidity (expressed as tartaric acid) range, relative standard deviations of results were estimated as about 0.7% after six-fold processing of typical wine samples, and results are in agreement with those obtained by a classical potentiometric titration, with relative errors <0.8%. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 26 条
  • [1] ABITCH SM, 1980, ANAL CHIM ACTA, V114, P247
  • [2] Development of a sequential microtitration system
    Alerm, L
    Bartroli, J
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (08) : 1394 - 1400
  • [3] [Anonymous], 1992, STAND METH EX WAT WA
  • [4] Single standard calibration and data processing in flow injection titration based on concentration gradients
    Araujo, MCU
    Santos, AV
    Honorato, RS
    [J]. JOURNAL OF AUTOMATIC CHEMISTRY, 1997, 19 (05): : 157 - 164
  • [5] AUTOMATED TITRATIONS USING A DISCONTINUOUS PROGRAMMED FLOW ANALYZER
    ARNOLD, DP
    PEACHEY, RM
    PETTY, JD
    SWEATMAN, DR
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (18) : 2109 - 2116
  • [6] CONTROLLED DYNAMIC TITRATOR WITH CONDUCTOMETRIC INDICATION
    ASHWORTH, MRF
    WALISCH, W
    BECKER, W
    STUTZ, F
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1975, 273 (04): : 275 - 281
  • [8] BARTROLI J, 1995, ANAL LETT, V28, P1483
  • [9] CONTINUOUS AUTOMATED BURETLESS TITRATOR WITH DIRECT READOUT
    BLAEDEL, WJ
    LAESSIG, RH
    [J]. ANALYTICAL CHEMISTRY, 1964, 36 (08) : 1617 - &
  • [10] FLOW METHOD FOR THE TITRATION OF WEAK ACIDS OR WEAK BASES USING LINEAR TITRATION PLOTS
    CALATAYUD, JM
    FALCO, PC
    ALBERT, RM
    [J]. ANALYST, 1987, 112 (07) : 1063 - 1066