Single standard calibration and data processing in flow injection titration based on concentration gradients

被引:12
作者
Araujo, MCU [1 ]
Santos, AV [1 ]
Honorato, RS [1 ]
机构
[1] UNIV ESTADUAL CAMPINAS, INST QUIM, BR-13081970 CAMPINAS, SP, BRAZIL
来源
JOURNAL OF AUTOMATIC CHEMISTRY | 1997年 / 19卷 / 05期
关键词
D O I
10.1155/S1463924697000163
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes use of gradients of concentration generated in flow injection (FT) systems to perform determinations based on points where the concentration of titrant and analyte are at stoichiometric ratio. Two procedures were developed. In one procedure the titrant is injected in a FI manifold and merges with the sample which is continuously pumped towards the detector. In the other procedure the sample is injected and merged with the titrant which is continuously pumped. Both techniques make use of concentration gradients of the sample or titrant generated in FI manifolds that contain a mixing chamber. This gradient is calibrated employing only one standard solution (usually the titrant) in order to convert any detector signal, obtained in the elapsed time after injection, to instantaneous concentration values. The flow system is microcomputer controlled and data are treated to locate points where the concentration of titrant and analyte are at the stoichiometric ratio. These points are found in abrupt changes of the signal x concentration curves obtained in the presence of the reaction. The method has been evaluated for determination of Fe(II) and acetic acid by, spectrophotometric and conductimetric detection, respectively. Results shore, a mean relative standard deviation bower than 1%, an average accuracy of 1% and a high sampling processing capability (40 to 60 samples pet hour).
引用
收藏
页码:157 / 164
页数:8
相关论文
共 21 条
  • [1] ABITCH SM, 1980, ANAL CHIM ACTA, V114, P247
  • [2] [Anonymous], COMPENDIUM ANAL NOME
  • [3] A FAST PROCEDURE FOR STANDARD ADDITIONS IN FLOW-INJECTION ANALYSIS
    ARAUJO, MCU
    PASQUINI, C
    BRUNS, RE
    ZAGATTO, EAG
    [J]. ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) : 337 - 343
  • [4] CONTROLLED DYNAMIC TITRATOR WITH CONDUCTOMETRIC INDICATION
    ASHWORTH, MRF
    WALISCH, W
    BECKER, W
    STUTZ, F
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1975, 273 (04): : 275 - 281
  • [6] Basset J., 1978, VOGELS TXB QUANTITAT
  • [7] CONTINUOUS AUTOMATED BURETLESS TITRATOR WITH DIRECT READOUT
    BLAEDEL, WJ
    LAESSIG, RH
    [J]. ANALYTICAL CHEMISTRY, 1964, 36 (08) : 1617 - &
  • [8] FLOW-REVERSAL FLOW-INJECTION ANALYSIS - ENHANCEMENT OF FLOW-INJECTION TITRATIONS
    CLARK, GD
    ZABLE, J
    RUZICKA, J
    CHRISTIAN, GD
    [J]. TALANTA, 1991, 38 (02) : 119 - 124
  • [9] AUTOMATED GRAVIMETRIC MANAGEMENT OF SOLUTIONS .1. HIGH-PERFORMANCE MICROCOMPUTER-CONTROLLED GRAVIMETRIC BURET
    CUNHA, IBS
    PASQUINI, C
    [J]. ANALYST, 1992, 117 (05) : 905 - 911
  • [10] deAraujo MCU, 1996, QUIM NOVA, V19, P86