Self-assembled monolayers as the coating in a quartz piezoelectric crystal immunosensor to detect salmonella in aqueous solution

被引:164
作者
Fung, YS [1 ]
Wong, YY [1 ]
机构
[1] Univ Hong Kong, Dept Chem, Hong Kong, Hong Kong, Peoples R China
关键词
D O I
10.1021/ac010655y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new procedure based on the self-assembled monolayers (SAM) of alkanethiols was developed to immobilize antibodies onto gold electrodes of a quartz crystal microbalance (QCM) for detecting Salmonella paratyphi A. The procedure includes (1) chemisorption of 3-mercaptopropionic acid (MPA) at electrode surfaces to produce a carboxylic acid terminated monolayer, (2) activation by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydrosuccinimide (NHS) to generate a stable acyl amino ester intermediate, and (3) condensation of antibodies after aminolysis of the NHS adduct. Activation by two coupling agents (EDC and NHS) was shown to enhance the stability of the coating and facilitate the formation of a suitable intermediate to condense antibodies reproducibly and densely at the SAM, leading to high sensitivity and good precision of the developed immunosensor. With 50 min incubation under continuous monitoring, working ranges from 10(2) to 10(5) cells/mL with repeatability < 10% RSD were obtained. On the basis of S/N = 3, the detection limit was 1.7 x 10(2) cells/mL. The MO2 piezoimmunosensor developed was specific to differentiate S. paratyphi A against Escherichia coli and other serogroups of Salmonella that are commonly present together.
引用
收藏
页码:5302 / 5309
页数:8
相关论文
共 50 条
  • [11] Characterising the formation of a bioelectrochemical interface at a self-assembled monolayer using X-ray photoelectron spectroscopy
    Jiang, L
    Glidle, A
    Griffith, A
    McNeil, CJ
    Cooper, JM
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1997, 42 (01): : 15 - 23
  • [12] GLUCOSE SENSITIVITY OF THIOL MODIFIED GOLD ELECTRODES HAVING IMMOBILIZED GLUCOSE-OXIDASE AND 2-AMINOETHYLFERROCENE
    KAJIYA, Y
    OKAMOTO, T
    YONEYAMA, H
    [J]. CHEMISTRY LETTERS, 1993, (12) : 2107 - 2110
  • [13] FREQUENCY OF A QUARTZ MICROBALANCE IN CONTACT WITH LIQUID
    KANAZAWA, KK
    GORDON, JG
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (08) : 1770 - 1771
  • [14] KONIG B, 1993, ANAL LETT, V26, P1567, DOI 10.1080/00032719308021481
  • [15] AN IMPROVED ENZYME-IMMUNOASSAY FOR THE DETECTION OF SALMONELLA
    MATTINGLY, JA
    GEHLE, WD
    [J]. JOURNAL OF FOOD SCIENCE, 1984, 49 (03) : 807 - 809
  • [16] Foodborne pathogens
    McNamara, AM
    [J]. JOURNAL OF URBAN HEALTH-BULLETIN OF THE NEW YORK ACADEMY OF MEDICINE, 1998, 75 (03): : 503 - 505
  • [17] Food-related illness and death in the United States
    Mead, PS
    Slutsker, L
    Dietz, V
    McCaig, LF
    Bresee, JS
    Shapiro, C
    Griffin, PM
    Tauxe, RV
    [J]. EMERGING INFECTIOUS DISEASES, 1999, 5 (05) : 607 - 625
  • [18] MECHANISM OF AMIDE FORMATION BY CARBODIIMIDE FOR BIOCONJUGATION IN AQUEOUS-MEDIA
    NAKAJIMA, N
    IKADA, Y
    [J]. BIOCONJUGATE CHEMISTRY, 1995, 6 (01) : 123 - 130
  • [19] Selective desorption of 3-mercaptopropionic acid from a mixed monolayer with hexadecanethiol assembled on a gold electrode
    Nishizawa, M
    Sunagawa, T
    Yoneyama, H
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 436 (1-2): : 213 - 218
  • [20] FREQUENCY-SHIFTS OF PIEZOELECTRIC QUARTZ CRYSTALS IMMERSED IN ORGANIC LIQUIDS