A new double modeling approach for dynamic cardiac PET studies using noise and spillover contaminated LV measurements

被引:29
作者
Feng, DG
Li, XJ
Huang, SC
机构
[1] UNIV CALIF LOS ANGELES, SCH MED, DEPT MOLEC & MED PHARMACOL, DIV NUCL MED & BIOPHYS, LOS ANGELES, CA 90024 USA
[2] UNIV CALIF LOS ANGELES, SCH MED, DEPT BIOMATH, LOS ANGELES, CA 90024 USA
基金
澳大利亚研究理事会;
关键词
D O I
10.1109/10.486290
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new double modeling approach for dynamic cardiac, studies with positron emission tomography (PET) to estimate physiological parameters is proposed. This approach is exemplified by tracer fluorodeoxyglucose (FDG) studies and estimation of myocardial metabolic rate of glucose (MMRGlc). A separate input function model characterising the tracer kinetics in plasma is used to account for the measurement noise and spillover problems of the input curve obtained from the left ventricular region on the PET images. Measured left ventricle (LV) plasma time-activity and tissue time-activity curves are fitted simultaneously with cross contaminations by this input function model and the FDG model. The results indicate that the MMRGlc can be estimated much more accurately and reliably by this new approach. Compared with the traditional method, an improvement of about 20% in the estimated MMRGlc was achieved when the bidirectional spillover fractions are 20% at different noise levels studied. This new double modeling approach using two models fitting both the input and the output functions simultaneously is expected to he generally applicable to a broad range of system modeling.
引用
收藏
页码:319 / 327
页数:9
相关论文
共 22 条
[1]   NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY [J].
BERGMANN, SR ;
HERRERO, P ;
MARKHAM, J ;
WEINHEIMER, CJ ;
WALSH, MN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :639-652
[2]   THE EFFECTS OF MEASUREMENT ERRORS IN THE PLASMA RADIOACTIVITY CURVE ON PARAMETER-ESTIMATION IN POSITRON EMISSION TOMOGRAPHY [J].
CHEN, K ;
HUANG, SC ;
YU, DC .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (09) :1183-1200
[3]  
CHOI Y, 1991, J NUCL MED, V32, P733
[4]   MODELS FOR COMPUTER-SIMULATION STUDIES OF INPUT FUNCTIONS FOR TRACER KINETIC MODELING WITH POSITRON EMISSION TOMOGRAPHY [J].
FENG, D ;
HUANG, SC ;
WANG, XM .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1993, 32 (02) :95-110
[5]   A COMPUTER-SIMULATION STUDY ON THE EFFECTS OF INPUT FUNCTION MEASUREMENT NOISE IN TRACER KINETIC MODELING WITH POSITRON EMISSION TOMOGRAPHY (PET) [J].
FENG, DG ;
WANG, XM .
COMPUTERS IN BIOLOGY AND MEDICINE, 1993, 23 (01) :57-68
[6]  
Gambhir S S, 1990, THESIS U CALIFORNIA
[7]  
GAMBHIR SS, 1989, J NUCL MED, V30, P359
[8]   EFFECTS OF TEMPORAL SAMPLING, GLUCOSE METABOLIC RATES, AND DISRUPTIONS OF THE BLOOD-BRAIN-BARRIER ON THE FDG MODEL WITH AND WITHOUT A VASCULAR COMPARTMENT - STUDIES IN HUMAN-BRAIN TUMORS WITH PET [J].
HAWKINS, RA ;
PHELPS, ME ;
HUANG, SC .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (02) :170-183
[9]  
HENZE E, 1983, J NUCL MED, V24, P987
[10]   MEASUREMENT OF MYOCARDIAL BLOOD-FLOW WITH POSITRON EMISSION TOMOGRAPHY - CORRECTION FOR COUNT SPILLOVER AND PARTIAL VOLUME EFFECTS [J].
HERRERO, P ;
MARKHAM, J ;
MYEARS, DW ;
WEINHEIMER, CJ ;
BERGMANN, SR .
MATHEMATICAL AND COMPUTER MODELLING, 1988, 11 :807-812