Truly hybrid interventional MR/x-ray system: Investigation of in vivo applications

被引:34
作者
Fahrig, R
Butts, K
Wen, ZF
Saunders, R
Kee, ST
Sze, DY
Daniel, BL
Laerum, F
Pelc, NJ
机构
[1] Stanford Univ, Dept Radiol, Lucas MRS Ctr, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Phys, Stanford, CA 94305 USA
[3] GE Co, Med Syst, Milwaukee, WI 53201 USA
[4] Univ Oslo, Natl Hosp, N-0316 Oslo, Norway
关键词
D O I
10.1016/S1076-6332(03)80702-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this study was to provide in vivo demonstrations of the functionality of a truly hybrid interventional x-ray/magnetic resonance (MR) system. Materials and Methods. A digital flat-panel x-ray system (1,024(2) array of 200 mum pixels, 30 frames per second) was integrated into an interventional 0.5-T magnet. The hybrid system is capable of MR and x-ray imaging of the same field Of view without patient movement. Two intravascular procedures were performed in a 22-kg porcine model: placement of a transjugular intrahepatic portosystemic shunt (TIPS) (x-ray-guided catheterization of the hepatic vein, MR fluoroscopy-guided portal puncture, and x-ray-guided stent placement) and mock chemoembolization (x-ray-guided subselective catheterization of a renal artery branch and MR evaluation of perfused volume). Results. The resolution and frame rate of the x-ray fluoroscopy images were sufficient to visualize and place devices, including nitinol guidewires (0.016-0.035-inch diameter) and stents and a 2.3-F catheter. Fifth-order branches of the renal artery could be seen. The quality of both real-time (3.5 frames per second) and standard MR images was not affected by the x-ray system. During MR-guided TIPS placement, the trocar and the portal vein could be easily visualized, allowing successful puncture from hepatic to portal vein. Conclusion. Switching back and forth between x-ray and MR imaging modalities without requiring movement of the patient was demonstrated. The integrated nature of the system could be especially beneficial when x-ray and MR image guidance are used iteratively.
引用
收藏
页码:1200 / 1207
页数:8
相关论文
共 18 条
[1]   Interventional magnetic resonance - Initial clinical experience with a 1.5-tesla magnetic resonance system combined with c-arm fluoroscopy [J].
Adam, G ;
Neuerburg, J ;
Bucker, A ;
Glowinski, A ;
Vorwerk, D ;
Stargardt, A ;
VanVaals, JJ ;
Gunther, RW .
INVESTIGATIVE RADIOLOGY, 1997, 32 (04) :191-197
[2]  
BUTTS K, 1999, RSNA EJ, V3
[3]  
Fahrig R, 2001, J MAGN RESON IMAGING, V13, P294, DOI 10.1002/1522-2586(200102)13:2<294::AID-JMRI1042>3.0.CO
[4]  
2-X
[5]   COMPLICATIONS OF TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT - A COMPREHENSIVE REVIEW [J].
FREEDMAN, AM ;
SANYAL, AJ ;
TISNADO, J ;
COLE, PE ;
SHIFFMAN, ML ;
LUKETIC, VA ;
PURDUM, PP ;
DARCY, MD ;
POSNER, MP .
RADIOGRAPHICS, 1993, 13 (06) :1185-1210
[6]   Performance characteristics of an amorphous silicon flat panel X-ray imaging detector [J].
Granfors, PR .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :480-490
[7]   Brain biopsy using high-field strength interventional magnetic resonance imaging [J].
Hall, WA ;
Martin, AJ ;
Liu, HY ;
Nussbaum, ES ;
Maxwell, RE ;
Truwit, CL .
NEUROSURGERY, 1999, 44 (04) :807-813
[8]  
IVAN AJ, 2000, Patent No. 6031888
[9]   MR-guided transjugular portosystemic shunt placement in a swine model [J].
Kee, ST ;
Rhee, JS ;
Butts, K ;
Daniel, B ;
Pauly, J ;
Kerr, A ;
O'Sullivan, GJ ;
Sze, DY ;
Razavi, MK ;
Semba, CP ;
Herfkens, RJ ;
Dake, MD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (05) :529-535
[10]   Real-time interactive MRI on a conventional scanner [J].
Kerr, AB ;
Pauly, JM ;
Hu, BS ;
Li, KC ;
Hardy, CJ ;
Meyer, CH ;
Macovski, A ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :355-367