Application of semipermeable membrane device for assessing toxicity in drinking water

被引:17
作者
Gilli, G
Schilirò, T
Pignata, C
Traversi, D
Carraro, E
Baiocchi, C
Aigotti, R
Giacosa, D
Fea, E
机构
[1] Univ Turin, Dept Publ Hlth & Microbiol, I-10126 Turin, Italy
[2] Univ Piemonte Orientale, Dept Sci & Adv Technol, Alessandria, Italy
[3] Univ Turin, Dept Analyt Chem, Turin, Italy
[4] SMAT, Soc Metropolitana Acque, Turin, Italy
关键词
semipermeable membrane devices (SPMDs); toxicity; genotoxicity; polycyclic aromatic hydrocarbon (PAH);
D O I
10.1016/j.chemosphere.2005.03.085
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Semipermeable, membrane devices (SPMDs) mimic passive diffusive transport of bioavailable hydrophobic organic compounds through biological membranes and their partitioning between lipids and environmental levels. Our study was developed on a surface water treatment plant based in Turin, Northern Italy. The investigated plant treats Po River surface water and it supplies about 20% of the drinking water required by Turin city (about one million inhabitants). Surface water (input) and drinking water (output) were monitored with SPMDs from October 2001 to January 2004, over a period of 30 days. The contaminant residues, monthly extracted from SPMDs by dialysis in organic solvent, were tested with the Microtox(TM) acute toxic test and with the Ames mutagenicity test. Same extracts were also analyzed with gaschromatography-mass spectrometry technique in order to characterise the organic pollutants sampled, especially Polycyclic Aromatic Hydrocarbons (PAHs). Although the PAHs mean concentration is about one hundred times lower in the output samples, the mean toxic units are similar in drinking and surface water. Our data indicate that the SPMD is a suitable tool to assess the possible toxicity in drinking water. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1691 / 1699
页数:9
相关论文
共 27 条
[11]   Interpreting results from field deployments of semipermeable membrane devices [J].
Louch, J ;
Allen, G ;
Erickson, C ;
Wilson, G ;
Schmedding, D .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (06) :1202-1207
[12]   REVISED METHODS FOR THE SALMONELLA MUTAGENICITY TEST [J].
MARON, DM ;
AMES, BN .
MUTATION RESEARCH, 1983, 113 (3-4) :173-215
[13]  
MCCARTHY KA, 1999, 994051 USGS WAT RES
[14]  
*MICROTOX, 1995, MICR AC TOX BAS TEST
[15]   RELATIONSHIP BETWEEN BIOCONCENTRATION IN FISH AND STERIC FACTORS OF HYDROPHOBIC CHEMICALS [J].
OPPERHULZEN, A ;
VANDERVELDE, EW ;
GOBAS, FAPC ;
LIEM, DAK ;
VANDERSTEEN, JMD ;
HUTZINGER, O .
CHEMOSPHERE, 1985, 14 (11-12) :1871-1896
[16]   DIHALOACETONITRILES IN DUTCH DRINKING WATERS [J].
PETERS, RJ ;
DELEER, EW ;
DEGALAN, L .
WATER RESEARCH, 1990, 24 (06) :797-800
[17]   Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants [J].
Petty, JD ;
Orazio, CE ;
Huckins, JN ;
Gale, RW ;
Lebo, JA ;
Meadows, JC ;
Echols, KR ;
Cranor, WL .
JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (01) :83-95
[18]   An approach for assessment of water quality using semipermeable membrane devices (SPMDs) and bioindicator tests [J].
Petty, JD ;
Jones, SB ;
Huckins, JN ;
Cranor, WL ;
Parris, JT ;
McTague, TB ;
Boyle, TP .
CHEMOSPHERE, 2000, 41 (03) :311-321
[19]  
Rehena Z., 1996, MUTAT RES, V367, P187
[20]   Biofouling confounds the uptake of trace organic contaminants by semi-permeable membrane devices (SPMDs) [J].
Richardson, BJ ;
Lam, PKS ;
Zheng, GJ ;
McClellan, KE ;
De Luca-Abbott, SB .
MARINE POLLUTION BULLETIN, 2002, 44 (12) :1372-1379