Infrared thermography for building diagnostics

被引:403
作者
Balaras, CA [1 ]
Argiriou, AA [1 ]
机构
[1] Natl Observ Athens, Grp Energy Conservat, Inst Environm Res & Sustainable Dev, I Metaxa & V Pavlou, GR-15236 Palaia Penteli, Hellas, Greece
关键词
infrared (IR); thermography; building diagnostics; energy audits; TOBUS;
D O I
10.1016/S0378-7788(01)00105-0
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The use of thermal infrared (IR) imaging is a valuable tool for inspecting and performing non-destructive testing of building elements, detecting where and how energy is leaking from a building's envelope, collecting data for clarifying the operating conditions of hard to reach heating, ventilating and air-conditioning (HVAC) installations, identifying problems with the electrical and mechanical installations under full-load operating conditions. IR inspections involve the detection of IR electromagnetic radiation emitted by the inspected object. The collected information can be used as part of other investigative procedures to identify potential problems, quantify potential energy savings, schedule interventions and set priorities for preventive and predictive maintenance or the need for immediate service to minimise the risk of failure, This paper reviews the main areas for using IR in building diagnostics with an emphasis on how it was implemented to support office building audits following the TOBUS methodology. Representative examples from building envelope, mechanical and electrical inspections in audited Hellenic office buildings are presented to demonstrate common problems and data interpretation. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:171 / 183
页数:13
相关论文
共 16 条
  • [1] Assessment of energy and natural resources conservation in office buildings using TOBUS
    Balaras, CA
    Droutsa, K
    Argiriou, AA
    Wittchen, K
    [J]. ENERGY AND BUILDINGS, 2002, 34 (02) : 135 - 153
  • [2] TOBUS - a European diagnosis and decision-making tool for office building upgrading
    Caccavelli, D
    Gugerli, H
    [J]. ENERGY AND BUILDINGS, 2002, 34 (02) : 113 - 119
  • [3] CHOWN GA, 1983, THERMOGRAPHIC IDENTI
  • [4] Infrared thermographic investigation procedures for four types of generic exterior wall assemblies
    Colantonio, A
    [J]. THERMOSENSE XXI, 1999, 3700 : 458 - 462
  • [5] Eads LG, 2000, ASHRAE J, V42, P51
  • [6] KAPLAN H, 1992, PRACTICAL APPL INFRA
  • [7] Emissivity measurement and temperature correction accuracy considerations
    Madding, RP
    [J]. THERMOSENSE XXI, 1999, 3700 : 393 - 401
  • [8] Thermographer-friendly equipment design for predictive maintenance - Baseline thermograms, thermal modeling, emissivity
    Madding, RP
    [J]. THERMOSENSE XXI, 1999, 3700 : 2 - 5
  • [9] Maldague XPV, 1993, NONDESTRUCTIVE EVALU
  • [10] *NETA, 2001, MTS01 NETA