Simultaneous determination of metal ion concentrations in binary mixtures with a multi-LED photometer

被引:17
作者
Hauser, PC [1 ]
Rupasinghe, TWT [1 ]
机构
[1] UNIV AUCKLAND,DEPT CHEM,AUCKLAND,NEW ZEALAND
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1997年 / 357卷 / 08期
关键词
FLOW-INJECTION ANALYSIS; SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION; LIGHT-EMITTING-DIODES; MULTICOMPONENT ANALYSIS; COPPER; IRON; DETECTORS; ALUMINUM; SYSTEM; NICKEL;
D O I
10.1007/s002160050304
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A compact photometer is based on up to seven different light-emitting diodes whose light is guided into a photometric cell by means of a fibre-optic coupler. The wavelength is selected by switching on the appropriate light source. The application of this multiwavelength photometer to the determination of binary metal ion samples is demonstrated using model mixtures. Solutions of Fe, Co, Cu, Ni, Cr and Mn were used in combination with several photometric reagents. It was found that the instrument yielded concentration measurements which were usually within a few percent of the correct concentration. These results are comparable to reported data obtained with conventional instruments for similar measurements. The application of the instrument for simultaneous determination in flow-injection analysis employing rapid computer controlled switching of the light-emitting diodes is also demonstrated. A limitation in the use of light-emitting diodes for the simultaneous determination was found to arise from the fact that in some instances non-linear calibration curves are obtained when employing light-emitting diodes as light sources. This occurs when the absorptivity of the measured compound changes over the emission band of the diodes. Multiple regression analysis is then not easily possible.
引用
收藏
页码:1056 / 1060
页数:5
相关论文
共 19 条
[1]   DIODE-ARRAY DETECTORS IN FLOW-INJECTION ANALYSIS - MIXTURE RESOLUTION BY MULTI-WAVELENGTH ANALYSIS [J].
BLANCO, M ;
GENE, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J .
TALANTA, 1987, 34 (12) :987-993
[2]   THE SIMULTANEOUS SPECIATION OF ALUMINUM AND IRON IN A FLOW-INJECTION SYSTEM [J].
CLARKE, N ;
DANIELSSON, LG .
ANALYTICA CHIMICA ACTA, 1995, 306 (01) :5-20
[3]   SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF NICKEL AND IRON IN COPPER-BASE ALLOY WITH BROMO-PADAP [J].
COSTA, ACS ;
FERREIRA, SLC ;
ANDRADE, MGM ;
LOBO, IP .
TALANTA, 1993, 40 (08) :1267-1271
[4]   LIGHT-EMITTING DIODE BASED FLOW-THROUGH OPTICAL-ABSORPTION DETECTORS [J].
DASGUPTA, PK ;
BELLAMY, HS ;
LIU, HH ;
LOPEZ, JL ;
LOREE, EL ;
MORRIS, K ;
PETERSEN, K ;
MIR, KA .
TALANTA, 1993, 40 (01) :53-74
[5]   THE DETERMINATION OF CU, NI, AND CO USING 2-(2-PYRIDYLAZO)-1-NAPHTOL-4-SULFONIC ACID BY MULTICOMPONENT FLOW-INJECTION ANALYSIS (MC-FIA) [J].
DOLEZEL, P ;
KUBAN, V .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1988, 53 (06) :1162-1171
[6]   SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF COPPER, NICKEL AND PALLADIUM BY FLOW-INJECTION ANALYSIS [J].
HAJHUSSEIN, AT ;
CHRISTIAN, GD .
ANALYST, 1986, 111 (01) :65-68
[7]  
Hauser PC, 1995, CHIMIA, V49, P492
[8]   A MULTIWAVELENGTH PHOTOMETER BASED ON LIGHT-EMITTING-DIODES [J].
HAUSER, PC ;
RUPASINGHE, TWT ;
CATES, NE .
TALANTA, 1995, 42 (04) :605-612
[9]   A DUAL-WAVELENGTH LIGHT-EMITTING DIODE BASED DETECTOR FOR FLOW-INJECTION ANALYSIS PROCESS ANALYZERS [J].
HUANG, JL ;
LIU, HH ;
TAN, AM ;
XU, JH ;
ZHAO, XN .
TALANTA, 1992, 39 (06) :589-592
[10]  
KANG SW, 1992, ANAL CHIM ACTA, V261, P197, DOI 10.1016/0003-2670(92)80191-9