Theoretical analysis of performance of a micro gas turbine co/trigeneration system for residential buildings in a tropical region

被引:28
作者
Basrawi, Firdaus [1 ]
Yamada, Takanobu [2 ]
Obara, Shin'ya [3 ]
机构
[1] Univ Malaysia Pahang, Fac Mech Engn, Pekan 26600, Pahang, Malaysia
[2] Kitami Inst Technol, Dept Mech Engn, Kitami, Hokkaido 0908507, Japan
[3] Kitami Inst Technol, Dept Elect & Elect Engn, Kitami, Hokkaido 0908507, Japan
关键词
Micro gas turbine; Cogeneration system; Trigeneration system; Energy efficiency; Emissions; Economic; FUEL-CELL; TRIGENERATION SYSTEM; EXERGY ANALYSIS; ENERGY; CHALLENGES; BIODIESEL; OIL;
D O I
10.1016/j.enbuild.2013.08.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study shows performance of micro gas turbine (MGT) based cogeneration system (CGS) and trigeneration system (TGS) in residential buildings located in the area with a tropical climate. Energy, economic and environmental performance of MGT-CGS and MGT-TGS were studied. MGT-CGS consists of an MGT and an exhaust heat exchanger (EHE), whereas MGT-TGS consists of an MGT, an EHE, an absorption heat pump and a heat storage. Heat storage was essential for storing heat generated during daytime to be utilized during night-time in which heat demand was higher. MGT-TGS was a better configuration compared to MGT-CGS because it can utilize more exhaust heat and had Energy Recovery Utilized Efficiency (eta(ER,utilized)) of 0.37 and 0.80 during daytime and night-time, respectively. Furthermore, the payback period for the MGT-TGS was also shorter than MGT-CGS, 13.8 years under highly subsidized electricity tariff. The MGT-TGS also had a higher Fuel Energy Saving Index FESI when compared to a gas turbine, but had a lower FESI when compared to a combined cycle gas turbine. MGT-CGS and MGT-TGS can also reduce pollutants especially NO,, emissions compared to conventional systems. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:108 / 117
页数:10
相关论文
共 48 条
[21]   Micro gas turbine thermodynamic and economic analysis up to 500 kWe size [J].
Galanti, Leandro ;
Massardo, Aristide F. .
APPLIED ENERGY, 2011, 88 (12) :4795-4802
[22]  
Gas Malaysia, TAR RAT
[23]   Thermodynamic analysis of a trigeneration system consisting of a micro gas turbine and a double effect absorption chiller [J].
Huicochea, Armando ;
Rivera, Wilfrido ;
Gutierrez-Urueta, Geydy ;
Caries Bruno, Joan ;
Coronas, Alberto .
APPLIED THERMAL ENGINEERING, 2011, 31 (16) :3347-3353
[24]  
International Energy Agency, 2006, WORLD EN OUTL, P37
[25]   Bottoming micro-Rankine cycles for micro-gas turbines [J].
Invernizzi, Costante ;
Iora, Paolo ;
Silva, Paolo .
APPLIED THERMAL ENGINEERING, 2007, 27 (01) :100-110
[26]   Performance analysis for the part-load operation of a solid oxide fuel cell-micro gas turbine hybrid system [J].
Komatsu, Y. ;
Kimijima, S. ;
Szmyd, J. S. .
ENERGY, 2010, 35 (02) :982-988
[27]  
Kubota T., 2006, J ENV ENG T ARCHITEC, V608, P81
[28]   Life cycle cost analysis of fuel cell based cogeneration system for residential application in Malaysia [J].
Mahlia, T. M. I. ;
Chan, P. L. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (01) :416-426
[29]   Performance analysis of a trigeneration system based on a micro gas turbine and an air-cooled, indirect fired, ammonia-water absorption chiller [J].
Moya, M. ;
Bruno, J. C. ;
Eguia, P. ;
Torres, E. ;
Zamora, I. ;
Coronas, A. .
APPLIED ENERGY, 2011, 88 (12) :4424-4440
[30]   Biodiesel fuel in diesel micro-turbine engines: Modelling and experimental evaluation [J].
Nascimento, Marco A. R. ;
Lora, Electo S. ;
Correa, Paulo S. P. ;
Andrade, Rubenildo V. ;
Rendon, Manuel A. ;
Venturini, Osvaldo J. ;
Ramirez, Guido A. S. .
ENERGY, 2008, 33 (02) :233-240