Age dependence of ultrasonically induced lung hemorrhage in mice

被引:57
作者
Dalecki, D
Child, SZ
Raeman, CH
Cox, C
Penney, DP
Carstensen, EL
机构
[1] UNIV ROCHESTER,DEPT BIOSTAT,ROCHESTER,NY 14627
[2] UNIV ROCHESTER,DEPT PATHOL,ROCHESTER,NY 14627
[3] UNIV ROCHESTER,ROCHESTER CTR BIOMED ULTRASOUND,ROCHESTER,NY 14627
关键词
lung; ultrasound; hemorrhage; neonatal mouse; juvenile mouse; bioeffect;
D O I
10.1016/S0301-5629(97)00071-9
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Thresholds for ultrasonically induced lung hemorrhage were determined in neonatal mice (24-36 h old),juvenile mice (14 d old) and adult mice (8-10 weeks old) to assess whether or not the threshold for lung hemorrhage is dependent upon age, Ultrasonic exposures were at 1.15 MHz with a pulse length of 10 mu s, pulse repetition frequency of 100 Hz and a total exposure duration of 3 min, The threshold for lung hemorrhage occurred at a peak positive acoustic pressure of approximately 1 MPa for mice in all three age groups, Although the thresholds mere similar for neonatal, juvenile and adult mice, the sizes of the suprathreshold hemorrhages were significantly larger in adult mice than in neonatal or juvenile mice. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:767 / 776
页数:10
相关论文
共 16 条
[1]   Thresholds for ultrasonically induced lung hemorrhage in neonatal swine [J].
Baggs, R ;
Penney, DP ;
Cox, C ;
Child, SZ ;
Raeman, CH ;
Dalecki, D ;
Carstensen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (01) :119-128
[2]   Bioeffects of positive and negative acoustic pressures in vivo [J].
Bailey, MR ;
Dalecki, D ;
Child, SZ ;
Raeman, CH ;
Penney, DP ;
Blackstock, DT ;
Carstensen, EL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 100 (06) :3941-3946
[3]   LUNG DAMAGE FROM EXPOSURE TO PULSED ULTRASOUND [J].
CHILD, SZ ;
HARTMAN, CL ;
SCHERY, LA ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (08) :817-825
[4]  
COX C, 1984, APPL STAT-J ROY ST C, V33, P18
[5]   Hemolysis in vivo from exposure to pulsed ultrasound [J].
Dalecki, D ;
Raeman, CH ;
Child, SZ ;
Cox, C ;
Francis, CW ;
Meltzer, RS ;
Carstensen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02) :307-313
[6]  
DALECKI D, 1997, ULTRASOUND MED BIOL, P23
[7]  
DUNN F, 1977, ACUSTICA, V38, P58
[8]   EFFECTS OF PULSED ULTRASOUND ON THE MOUSE NEONATE - HIND-LIMB PARALYSIS AND LUNG HEMORRHAGE [J].
FRIZZELL, LA ;
CHEN, E ;
LEE, C .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (01) :53-63
[9]   MICROSCOPIC LUNG ALTERATIONS AND REDUCTION OF RESPIRATION RATE IN INSONATED ANESTHETIZED SWINE [J].
HARRISON, GH ;
EDDY, HA ;
WANG, JP ;
LIBERMAN, FZ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (07) :981-983
[10]   LUNG DAMAGE FROM EXPOSURE TO THE FIELDS OF AN ELECTROHYDRAULIC LITHOTRIPTER [J].
HARTMAN, C ;
CHILD, SZ ;
MAYER, R ;
SCHENK, E ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (07) :675-679