Hemolysis in vivo from exposure to pulsed ultrasound

被引:98
作者
Dalecki, D
Raeman, CH
Child, SZ
Cox, C
Francis, CW
Meltzer, RS
Carstensen, EL
机构
[1] UNIV ROCHESTER,DEPT BIOSTAT,ROCHESTER,NY 14627
[2] UNIV ROCHESTER,DEPT CARDIOL,ROCHESTER,NY 14627
[3] UNIV ROCHESTER,DEPT MED,HEMATOL UNIT,ROCHESTER,NY 14627
[4] UNIV ROCHESTER,ROCHESTER CTR BIOMED ULTRASOUND,ROCHESTER,NY 14627
关键词
ultrasound; hemolysis; contrast agent; bioeffect;
D O I
10.1016/S0301-5629(96)00203-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasonically induced hemolysis in vivo was studied when a commercial ultrasound contrast agent, Albunex(R), was present in the blood, Murine hearts were exposed for 5 min at either 1.15 or 2.35 MHz with a pulse length of 10 mu s and pulse repetition frequency of 100 Hz, During the exposure period, four boluses of Albunex(R) were injected into a tail vein for a total of similar to 0.1 mL of Albunex(R), Following exposure, blood was collected by heart puncture and centrifuged, and the plasma was analyzed for hemoglobin concentration, With Albunex(R) present in the blood, the threshold for hemolysis at 1.15 MHz was 3.0 +/- 0.8 MPa (mean +/- SD) peak positive pressure (similar to 1.9 MPa negative pressure, similar to 180 W cm(-2) pulse average intensity), For the highest exposure levels (10 MPa peak positive pressure at the surface of the animal), the mean value for hemolysis was similar to 4% at 1.15 MHz and 0.46% at 2.35 MHz, i.e., the threshold at 2.35 MHz is > 10 MPa peak positive pressure, In contrast, hemolysis in control mice receiving saline injections at 10 MPa or sham-exposed (0 MPa) mice receiving Albunex(R) was similar to 0.4%. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:307 / 313
页数:7
相关论文
共 13 条
[1]   Hemolysis of albunex-supplemented, 40% hematocrit human erythrocytes in vitro by 1-MHz pulsed ultrasound: Acoustic pressure and pulse length dependence [J].
Brayman, AA ;
Azadniv, M ;
Cox, C ;
Miller, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (07) :927-938
[2]   EFFECT OF A STABILIZED MICROBUBBLE ECHO CONTRAST AGENT ON HEMOLYSIS OF HUMAN ERYTHROCYTES EXPOSED TO HIGH-INTENSITY PULSED ULTRASOUND [J].
BRAYMAN, AA ;
AZADNIV, M ;
MAKIN, IRS ;
MILLER, MW ;
CARSTENSEN, EL ;
CHILD, SZ ;
RAEMAN, CH ;
MELTZER, RS ;
EVERBACH, EC .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1995, 12 (01) :13-21
[3]   LYSIS OF ERYTHROCYTES BY EXPOSURE TO CW ULTRASOUND [J].
CARSTENSEN, EL ;
KELLY, P ;
CHURCH, CC ;
BRAYMAN, AA ;
CHILD, SZ ;
RAEMAN, CH ;
SCHERY, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (02) :147-165
[4]   LUNG DAMAGE FROM EXPOSURE TO PULSED ULTRASOUND [J].
CHILD, SZ ;
HARTMAN, CL ;
SCHERY, LA ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (08) :817-825
[5]   INTESTINAL HEMORRHAGE FROM EXPOSURE TO PULSED ULTRASOUND [J].
DALECKI, D ;
RAEMAN, CH ;
CHILD, SZ ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (08) :1067-1072
[6]   EFFECTS OF PULSED ULTRASOUND ON THE FROG-HEART .1. THRESHOLDS FOR CHANGES IN CARDIAC-RHYTHM AND AORTIC PRESSURE [J].
DALECKI, D ;
KELLER, BB ;
RAEMAN, CH ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (05) :385-390
[7]  
Drabkin DL, 1932, J BIOL CHEM, V98, P719
[8]  
DUNN F, 1977, ACUSTICA, V38, P58
[9]  
IVEY JA, 1997, IN PRESS ULTRASOUND
[10]  
MACROBBIE AG, 1997, IN PRESS ULTRASOUND