Reduction in MRSA environmental contamination with a portable HEPA-filtration unit

被引:42
作者
Boswell, TC [1 ]
Fox, PC [1 ]
机构
[1] Nottingham City Hosp NHS Trust, Dept Microbiol, Nottingham NG5 1PB, England
关键词
MRSA; settle plates; HEPA filtration; environmental contamination;
D O I
10.1016/j.jhin.2005.11.011
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
There is renewed interest in the hospital environment as a potentially important factor for cross-infection with methicillin-resistant Staphylococcus aureus (MRSA) and other nosocomial pathogens. The aim of this study was to evaluate the effectiveness of a portable high-efficiency particulate air(HEPA)-filtration unit (IQAir Cleanroom H13, Incen AG, Goldach, Switzerland) at reducing MRSA environmental surface contamination within a clinical, setting. The MRSA contamination rate on horizontal surfaces was assessed with agar settle plates in ward side-rooms of three patients who were heavy MRSA dispersers. Contamination rates were measured at different air filtration rates (60-235 m(3)/h) and compared with no air filtration using Poisson repression. Without air filtration, between 80% and 100% of settle plates were positive for MRSA, with the mean number of MRSA colony-forming units (cfu)/10-h exposure/plate ranging from 4.1 to 27.7. Air filtration at a rate of 140 m(3)/h (one patient) and 235 m(3)/h (two patients), resulted in a highly significant decrease in contamination rates compared with no air filtration (adjusted rate ratios 0.037, 0.099 and 0.248, respectively; P < 0.001 for each). A strong association was demonstrated between the rate of air filtration and the mean number of MRSA cfu/10-h exposure/plate (P for trend < 0.001). In conclusion, this portable HEPA-filtration unit can significantly reduce MRSA environmental contamination within patient isolation rooms, and this may prove to be a useful. addition to existing MRSA infection control measures. (c) 2005 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:47 / 54
页数:8
相关论文
共 16 条
  • [1] Ayliffe GAJ, 1998, J HOSP INFECT, V39, P253, DOI 10.1016/S0195-6701(98)90293-6
  • [2] Environmental contamination due to methicillin-resistant Staphylococcus aureus (MRSA)
    Blythe, D.
    Keenlyside, D.
    Dawson, S. J.
    Galloway, A.
    [J]. JOURNAL OF HOSPITAL INFECTION, 1998, 38 (01) : 67 - 69
  • [3] Boyce J.M, 2003, INFECT CONT HOSP E S, V23, P1
  • [4] Boyce JM, 1997, INFECT CONT HOSP EP, V18, P622
  • [5] Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA):: a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination
    French, GL
    Otter, JA
    Shannon, KP
    Adams, NMT
    Watling, D
    Parks, MJ
    [J]. JOURNAL OF HOSPITAL INFECTION, 2004, 57 (01) : 31 - 37
  • [6] Ventilation grilles as a potential source of methicillin-resistant Staphylococcus aureus causing an outbreak in an orthopaedic ward at a district general hospital
    Kumari, DNP
    Haji, TC
    Keer, V
    Hawkey, PM
    Duncanson, V
    Flower, E
    [J]. JOURNAL OF HOSPITAL INFECTION, 1998, 39 (02) : 127 - 133
  • [7] EVALUATION OF A PORTABLE AIR PURIFIER
    LAWRENCE, JC
    LILLY, HA
    WILKINS, MD
    [J]. JOURNAL OF HYGIENE, 1981, 86 (02) : 203 - 208
  • [8] LAYTON MC, 1993, INFECT CONT HOSP EP, V14, P369
  • [9] Loo VG, 1996, INFECT CONT HOSP EP, V17, P360, DOI 10.1086/647317
  • [10] Effectiveness of in-room air filtration and dilution ventilation for tuberculosis infection control
    MillerLeiden, S
    Lobascio, C
    Nazaroff, WW
    Macher, JM
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1996, 46 (09) : 869 - 882