Multicenter evaluation of carotid artery stenting with a filter protection system

被引:137
作者
Al-Mubarak, N
Colombo, A
Gaines, PA
Iyer, SS
Corvaja, N
Cleveland, TJ
Macdonald, S
Brennan, C
Vitek, JJ
机构
[1] Lenox Hill Heart & Vasc Inst, New York, NY USA
[2] Ctr Cuore Colombus Intervent Cardiol, Milan, Italy
[3] Sheffield Vasc Inst, Sheffield, S Yorkshire, England
关键词
D O I
10.1016/S0735-1097(02)01692-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to evaluate the feasibility and safety of carotid artery stenting (CAS) with a filter protection system. BACKGROUND Neurologic events linked to the embolization of particulate matter to the cerebral circulation may complicate CAS. Strategies designed to capture embolic particles during carotid intervention are being evaluated for their efficacy in reducing the risk of these events. METHODS Between September 1999 and July 2001, a total of 162 patients (164 hemispheres) underwent CAS with filter protection (NeuroShield, MedNova Ltd., Galway, Ireland) according to prospective protocols evaluating the filter system at three institutions. RESULTS Angiographic success was achieved in 162 of the procedures (99%) and filter placement was successful in 154 (94%) procedures. Carotid access was unsuccessful in two cases (1%) and filter placement in eight cases (5%). Of the latter, five procedures were completed with no protection and three were completed using alternative protection devices. On an intention-to-treat basis, the overall combined 30-day rate of all-stroke and death was 2% (four events: two minor strokes and two deaths). This includes one minor stroke in a patient with failed filter placement and CAS completed without protection. There was one cardiac arrhythmic death and one death from hyperperfusion-related intracerebral hemorrhage. There were no major embolic strokes. CONCLUSIONS Carotid artery stenting with filter protection is technically feasible and safe. Early clinical outcomes appear to be favorable and need to be confirmed in a larger comparative study. (C) 2002 by the American College of Cardiology Foundation.
引用
收藏
页码:841 / 846
页数:6
相关论文
共 18 条
  • [1] Effect of the distal-balloon protection system on microembolization during carotid stenting
    Al-Mubarak, N
    Roubin, GS
    Vitek, JJ
    Iyer, SS
    New, G
    Leon, MB
    [J]. CIRCULATION, 2001, 104 (17) : 1999 - 2002
  • [2] Al-Mubarak N, 2000, Semin Vasc Surg, V13, P117
  • [3] Carotid stents are not a source of microemboli late after deployment
    Censori, B
    Camerlingo, M
    Casto, L
    Partziguian, T
    Caverni, L
    Bonaldi, G
    Mamoli, A
    [J]. ACTA NEUROLOGICA SCANDINAVICA, 2000, 102 (01): : 27 - 30
  • [4] Comparison of microembolism detected by transcranial Doppler and neuropsychological sequelae of carotid surgery and percutaneous transluminal angioplasty
    Crawley, F
    Stygall, J
    Lunn, S
    Harrison, M
    Brown, MM
    Newman, S
    [J]. STROKE, 2000, 31 (06) : 1329 - 1334
  • [5] Henry M, 2000, TEX HEART I J, V27, P150
  • [6] Mehran R, 2001, CIRCULATION, V104, P367
  • [7] GUIDELINES FOR CAROTID ENDARTERECTOMY - A MULTIDISCIPLINARY CONSENSUS STATEMENT FROM THE AD-HOC-COMMITTEE, AMERICAN-HEART-ASSOCIATION
    MOORE, WS
    BARNETT, HJM
    BEEBE, HG
    BERNSTEIN, EF
    BRENER, BJ
    BROTT, T
    CAPLAN, LR
    DAY, A
    GOLDSTONE, J
    HOBSON, RW
    KEMPCZINSKI, RF
    MATCHAR, DB
    MAYBERG, MR
    NICOLAIDES, AN
    NORRIS, JW
    RICOTTA, JJ
    ROBERTSON, JT
    RUTHERFORD, RB
    THOMAS, D
    TOOLE, JF
    TROUT, HH
    WIEBERS, DO
    [J]. STROKE, 1995, 26 (01) : 188 - 201
  • [8] Ohki T, 2001, J Invasive Cardiol, V13, P47
  • [9] Ex vivo human carotid artery bifurcation stenting: Correlation of lesion characteristics with embolic potential
    Ohki, T
    Marin, ML
    Lyon, RT
    Berdejo, GL
    Soundararajan, K
    Ohki, M
    Yuan, JG
    Faries, PL
    Wain, RA
    Sanchez, LA
    Suggs, WD
    Veith, FJ
    [J]. JOURNAL OF VASCULAR SURGERY, 1998, 27 (03) : 463 - 471
  • [10] Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: An ex vivo analysis
    Ohki, T
    Roubin, GS
    Veith, FJ
    Iyer, SS
    Brady, E
    [J]. JOURNAL OF VASCULAR SURGERY, 1999, 30 (06) : 1034 - 1042