共 25 条
Diagnosis of catheter-related bacteraemia: a prospective comparison of the time to positivity of hub-blood versus peripheral-blood cultures
被引:268
作者:
Blot, F
Nitenberg, G
Chachaty, E
Raynard, B
Germann, N
Antoun, S
Laplanche, A
Brun-Buisson, C
Tancrede, C
机构:
[1] Inst Gustave Roussy, Serv Reanimat Polyvalente, F-94805 Villejuif, France
[2] Inst Gustave Roussy, Serv Microbiol Med, F-94805 Villejuif, France
[3] Inst Gustave Roussy, Dept Biostat & Epidemiol, F-94805 Villejuif, France
[4] Hop Henri Mondor, Serv Reanimat Med, F-94010 Creteil, France
来源:
关键词:
D O I:
10.1016/S0140-6736(98)11134-0
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background A method of diagnosing catheter-related infection (CRI) without removing the catheter would be useful. An earlier positivity of central compared with peripheral venous-blood cultures may be associated with catheter-related bacteraemia. We evaluated prospectively the differential time to positivity (DTP) of paired blood cultures drawn simultaneously via the catheter hub and from a peripheral venous site. Methods Over a 14-month period in an intensive-care unit of a cancer referral centre, simultaneous hub-blood and peripheral-blood cultures (a mean of two per patient) were obtained from patients with a suspected CRI. According to clinical criteria and quantitative culture of the catheter tip, cases were classified as CRI or sepsis of other origin. At least one pair of hub-blood and peripheral-blood cultures was obtained within 48 h before catheter removal, and we recorded the DTP between hub-blood and peripheral-blood cultures with an automatic device for detection of blood culture positivity. Findings We analysed 93 catheters removed because of suspicion of CRI, in 28 episodes, the same micro-organisms were found in both hub-blood and peripheral-blood cultures. A diagnosis of definite bacteraemic CRI was made in 16 of the 17 patients in whom a positive hub-blood culture was detected at least 2 hours earlier than peripheral-blood culture. About half (9/17) of these episodes occurred in long-term (>30 days) devices. CRI was excluded in ten of the 11 patients with a DTP lower than 2 h. The DTP of paired blood cultures was significantly greater in patients with CRI than in others (p<10(-4)). A cut-off DTP value of 120 min had 91% specificity and 94% sensitivity for the diagnosis of CRI. Three of 17 episodes with only hub-blood culture positive were associated with CRI. Interpretation This prospective study suggests that measurement of the differential time to positivity between hub-blood and peripheral-blood cultures is a simple and reliable tool for in-situ diagnosis of catheter-related sepsis in cancer patients. Further studies are needed to confirm these data for short-term catheters.
引用
收藏
页码:1071 / 1077
页数:7
相关论文