Determination of tetracyclines with a modified beta-cyclodextrin based fluorosensor

被引:26
作者
Gong, ZL
Zhang, ZJ
机构
[1] SHAANXI NORMAL UNIV,DEPT CHEM,XIAN 710062,PEOPLES R CHINA
[2] NANJING UNIV,DEPT CHEM,NANJING 210093,PEOPLES R CHINA
基金
中国国家自然科学基金;
关键词
ethyl substituted beta-cyclodextrin; fluorosensor; tetracyclines;
D O I
10.1016/S0003-2670(97)00343-7
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
An ethyl substituted beta-cyclodextrin based fluorosensor was prepared for the determination of tetracyclines in clinial samples. The analytical performance characteristics of the proposed sensor for analysis of very low levels of tetracycline (TC), oxytetracycline and chlorotetracycline were as follows: the linear ranges were 9-800, 20-1000 and 25-1000 nM, respectively. The detection limits were 4.0, 7.5 and 9.0 nM. The relative standard deviation for 11 determinations of 1 mu M of each antibiotic was 1.1%. The proposed optosensor has a higher selectivity. Species existing in biological samples hardly interfered, and the main interferences were caused by some metal ions which can complex with TC and enhance its fluorescence. They could be masked by adding excess of EDTA. The recommended method has been successfully tested for determining tetracycline in clinical samples (urine and pharmaceutical preparations). (C) 1997 Elsevier Science B.V.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 15 条
[1]
ROOM-TEMPERATURE PHOSPHORESCENCE OPTOSENSOR FOR TETRACYCLINES [J].
ALAVAMORENO, F ;
DIAZGARCIA, ME ;
SANZMEDEL, A .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :637-644
[2]
SPECTROPHOTOMETRIC DETERMINATION OF OXYTETRACYCLINE BY FLOW-INJECTION [J].
ALWARTHAN, AA ;
ALTAMRAH, SA ;
SULTAN, SM .
ANALYST, 1991, 116 (02) :183-186
[3]
SPECTROFLUOROMETRIC DETERMINATION OF TETRACYCLINE AND ANHYDROTETRACYCLINE IN SERUM AND URINE [J].
CHANG, WB ;
ZHAO, YB ;
CI, YX ;
HU, LY .
ANALYST, 1992, 117 (08) :1377-1378
[4]
Evaluation of a narrow-bore HPLC column for trace level analysis of tetracyclinesa comparison with a conventional column [J].
CROUBELS, S ;
BAEYENS, W ;
VANPETEGHEM, C .
BIOMEDICAL CHROMATOGRAPHY, 1995, 9 (06) :251-294
[5]
KINETIC METHOD OF TETRACYCLINE AND OXYTETRACYCLINE ASSAY USING SPECTROPHOTOMETRIC MEASUREMENTS [J].
ELSAYED, MAH ;
BARARY, MH ;
MAHGOUB, H .
ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1985, 18 (11) :1357-1373
[6]
RETENTION BEHAVIOR OF SOME AROMATIC-COMPOUNDS ON CHEMICALLY BONDED CYCLODEXTRIN SILICA STATIONARY PHASE IN LIQUID-CHROMATOGRAPHY [J].
FUJIMURA, K ;
UEDA, T ;
ANDO, T .
ANALYTICAL CHEMISTRY, 1983, 55 (03) :446-450
[7]
FEASIBILITY OF FLUORESCENCE DETECTION OF TETRACYCLINE IN MEDIA MIXTURES EMPLOYING A FIBER OPTIC PROBE [J].
GLAZIER, SA ;
HORVATH, JJ .
ANALYTICAL LETTERS, 1995, 28 (15) :2607-2624
[8]
Cyclodextrin-based optosensor for the determination of riboflavin in pharmaceutical preparations [J].
Gong, ZL ;
Zhang, ZJ .
ANALYST, 1996, 121 (08) :1119-1122
[9]
SIMULTANEOUS DETERMINATION OF OXYTETRACYCLINE, TETRACYCLINE AND CHLORTETRACYCLINE IN ANIMAL-TISSUES USING LIQUID-CHROMATOGRAPHY, POSTCOLUMN DERIVATIZATION WITH ALUMINUM, AND FLUORESCENCE DETECTION [J].
MCCRACKEN, RJ ;
JOHN, W ;
BLANCHFLOWER, WJ ;
HAGGAN, SA ;
KENNEDY, DG .
ANALYST, 1995, 120 (06) :1763-1766
[10]
Spectrophotometric determination of drugs in pharmaceutical formulations with N-bromosuccinimide and celestine blue [J].
Sastry, CSP ;
Srinivas, KR ;
Prasad, KMMK .
MIKROCHIMICA ACTA, 1996, 122 (1-2) :77-86