Inertial sensor motion analysis of gait, sit-stand transfers and step-up transfers: differentiating knee patients from healthy controls

被引:47
作者
Bolink, S. A. A. N. [1 ]
van Laarhoven, S. N. [1 ]
Lipperts, M. [1 ]
Heyligers, I. C. [1 ]
Grimm, B. [1 ]
机构
[1] AHORSE Res Fdn, Dept Orthopaed, Atrium Med Ctr Heerlen, Heerlen, Netherlands
关键词
inertial sensor; motion analysis; outcome assessment; osteoarthritis; gait; sit-stand; step-up; PHYSICAL FUNCTION; ARTHROPLASTY; OSTEOARTHRITIS; MOVEMENT; HIP; WALKING; ACCELEROMETERS; VARIABILITY; KINEMATICS; ACCURACY;
D O I
10.1088/0967-3334/33/11/1947
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Patients undergoing total knee replacement for end stage knee osteoarthritis (OA) become increasingly younger and more demanding. Consequently, outcome assessment tools need to evolve toward objective performance-based measures. We applied a novel approach toward ambulatory biomechanical assessment of physical function using a single inertial sensor located at the pelvis to derive various motion parameters during activities of daily living. We investigated the potential of a clinically feasible battery of tests to define relevant parameters of physical function. We compared preoperative measures of end stage knee OA patients to healthy subjects. Our results show that measures of time yield the highest discriminative capacity to differentiate between groups. Additionally we found disease-dependent and task-specific alterations of movement for inertial sensor-derived motion parameters with good discriminative capacity. The inertial sensor's output quantities seem to capture another clinically relevant dimension of physical function that is supplementary to time. This study demonstrates the potential of inertial sensor-based motion analysis and provides a standardized test feasible for a routine clinical application in the longitudinal follow-up.
引用
收藏
页码:1947 / 1958
页数:12
相关论文
共 32 条
[1]
Interrater Reliability and Validity of the Stair Ascend/Descend Test in Subjects With Total Knee Arthroplasty [J].
Almeida, Gustavo J. ;
Schroeder, Carolyn A. ;
Gil, Alexandra B. ;
Fitzgerald, G. Kelley ;
Piva, Sara R. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (06) :932-938
[2]
Reliability and clinical correlates of 3D-accelerometry based gait analysis outcomes according to age and fall-risk [J].
Bautmans, Ivan ;
Jansen, Bart ;
Van Keymolen, Bart ;
Mets, Tony .
GAIT & POSTURE, 2011, 33 (03) :366-372
[3]
Functional evaluation of the TKA patient using the coordination and variability of rising [J].
Boonstra, M. C. ;
Jenniskens, A. T. ;
Barink, M. ;
van Uden, C. J. T. ;
Kooloos, J. G. M. ;
Verdonschot, N. ;
Malefijt, M. C. de Waal .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2007, 17 (01) :49-56
[4]
The accuracy of measuring the kinematics of rising from a chair with accelerometers and gyroscopes [J].
Boonstra, MC ;
van der Slikke, RMA ;
Keijsers, NLW ;
van Lummel, RC ;
Malefijt, MCD ;
Verdonschot, N .
JOURNAL OF BIOMECHANICS, 2006, 39 (02) :354-358
[5]
Sit-to-Stand Movement as a Performance-Based Measure for Patients With Total Knee Arthroplasty [J].
Boonstra, Miranda C. ;
Schwering, Paul J. A. ;
Malefijt, Maarten C. De Waal ;
Verdonschot, Nico .
PHYSICAL THERAPY, 2010, 90 (02) :149-156
[6]
Optimal inertial sensor location for ambulatory measurement of trunk inclination [J].
Faber, Gert S. ;
Kingma, Idsart ;
Bruijn, Sjoerd M. ;
van Dieen, Jaap H. .
JOURNAL OF BIOMECHANICS, 2009, 42 (14) :2406-2409
[7]
Persistence of altered movement patterns during a sit-to-stand task 1 year following unilateral total knee arthroplasty [J].
Farquhar, Sara J. ;
Reisman, Darcy S. ;
Snyder-Mackler, Lynn .
PHYSICAL THERAPY, 2008, 88 (05) :567-579
[8]
Sit-to-Stand 3 months after unilateral total knee arthroplasty: Comparison of self-selected and constrained conditions [J].
Farquhar, Sara J. ;
Kaufman, Kenton R. ;
Snyder-Mackler, Lynn .
GAIT & POSTURE, 2009, 30 (02) :187-191
[9]
Does centripetal acceleration affect trunk flexion monitoring by means of accelerometers? [J].
Giansanti, Daniele .
PHYSIOLOGICAL MEASUREMENT, 2006, 27 (10) :999-1008
[10]
Physiological motion monitoring: a wearable device and adaptative algorithm for sit-to-stand timing detection [J].
Giansanti, Daniele ;
Maccioni, Giovanni .
PHYSIOLOGICAL MEASUREMENT, 2006, 27 (08) :713-723