Does centripetal acceleration affect trunk flexion monitoring by means of accelerometers?

被引:14
作者
Giansanti, Daniele [1 ]
机构
[1] Ist Super Sanita, Dipartimento Tecnol & Salute, I-00161 Rome, Italy
关键词
patient-monitoring; accelerometer; gyroscopes; simulation; 3D rigid body position and orientation; human movement analysis; long-term monitoring; short-term monitoring; posturography;
D O I
10.1088/0967-3334/27/10/006
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Micro electro-mechanical and NANO technologies are sensibly reducing circuit and geometrical errors in accelerometer sensors. These sensors are often used as portable inclinometer sensors for trunk flexion monitoring in clinical applications. In this case, the rotating trunk generates centripetal acceleration, an error source that technological efforts cannot eliminate. This study analysed the effect of this source for typical human monitoring conditions by simulations and clinical validation using a wearable device with rate gyroscopes and accelerometers ( Giansanti and Maccioni 2005 Physiol. Meas. 26 689 - 705). Results showed that this error source did not affect long-term monitoring applications ( Mathie et al 2004 Physiol. Meas. 25 R1 - R20) but in the short-term monitoring caused a mean angular error equal to 0.96 degrees for the most critical single-task application represented by the sit-to-stand.
引用
收藏
页码:999 / 1008
页数:10
相关论文
共 18 条
[1]
Surface-marker cluster design criteria for 3-D bone movement reconstruction [J].
Cappozzo, A ;
Cappello, A ;
DellaCroce, U ;
Pensalfini, F .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) :1165-1174
[2]
CAPPOZZO A, 1982, THESIS U STRATHCLYDE
[3]
CARR R, 1991, ORDINARY DIFFERENTIA
[4]
Audio-biofeedback for balance improvement: An accelerometry-based system [J].
Chiari, L ;
Dozza, M ;
Cappello, A ;
Horak, FB ;
Macellari, V ;
Giansanti, D .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (12) :2108-2111
[5]
DAGOSTINO R, 1986, GODDNESS OF FIT TECH
[6]
EDWARDS CH, 1996, DIFFERENTIAL EQUATIO
[7]
Comparison of three different kinematic sensor assemblies for locomotion study [J].
Giansanti, D ;
Maccioni, G .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (05) :689-705
[8]
The development and test of a device for the reconstruction of 3-D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers [J].
Giansanti, D ;
Maccioni, G ;
Macellari, V .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (07) :1271-1277
[9]
Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data? [J].
Giansanti, D ;
Macellari, V ;
Maccioni, G ;
Cappozzo, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (04) :476-483
[10]
Physiological motion monitoring: a wearable device and adaptative algorithm for sit-to-stand timing detection [J].
Giansanti, Daniele ;
Maccioni, Giovanni .
PHYSIOLOGICAL MEASUREMENT, 2006, 27 (08) :713-723