Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data?

被引:73
作者
Giansanti, D
Macellari, V
Maccioni, G
Cappozzo, A
机构
[1] Ist Super Sanita, Lab Ingn Biomed, I-00161 Rome, Italy
[2] Ist Super Sanita, Lab Ingn Biomed, I-00161 Rome, Italy
[3] Univ Rome, Ist Sci Motorie, I-00161 Rome, Italy
关键词
accelerometer; accuracy; human movement analysis; simulation; 3-D rigid body position and orientation;
D O I
10.1109/TBME.2003.809490
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The analysis of the mechanics of the musculo-skeletal system during the execution of a motor task requires the determination of the instantaneous position and orientation of the body segments involved in relation to an inertial system of reference. By using adequately assembled uniaxial accelerometric sensors, an easy-to-manage measurement system can be obtained that estimates the three-dimensional position and orientation (P&O) of a body segment through an appropriate analytical model. However, the extent to which experimental errors, in particular accelerometers (ACs) assembly inaccuracies, affect such estimation has never been systematically investigated. This paper systematically analyzes the sensitivity of analytical models of body segment P&O reconstruction through a six-AC system and a nine-AC system to different sources of experimental error. We simulated and statistically assessed the performance of these models in the case of body segment motions typical of movements under muscular control. The results obtained indicated that the inaccuracy in the orientation of the individual AC's active axes and the offset error in the AC responses were the major sources of P&O estimation errors. In particular, no accurate estimation of position was possible with the analytical models analyzed. Under the motion conditions simulated in this study, no substantial advantages were found in using a nine-AC system rather than a six-AC system. Considering that the magnitudes of the simulated experimental errors were quite low (less than or equal to0.1 deg: AC's orientation; less than or equal to10(-4) m: uncertainty of the distance between two ACs; less than or equal to10(-2) ms(-2):random error; 0.5 . 10(-2) ms(-2):offset error), the results indicate that none of the two ACs systems analyzed is suitable for body segment P&O estimation in routine biomechanical applications.
引用
收藏
页码:476 / 483
页数:8
相关论文
共 18 条
[1]   BIOMECHANICAL INVESTIGATION OF WRIST KINEMATICS [J].
ANDREWS, JG ;
YOUM, Y .
JOURNAL OF BIOMECHANICS, 1979, 12 (01) :83-93
[2]   Surface-marker cluster design criteria for 3-D bone movement reconstruction [J].
Cappozzo, A ;
Cappello, A ;
DellaCroce, U ;
Pensalfini, F .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) :1165-1174
[3]  
CAPPOZZO A, 1982, THESIS U STRATHCLYDE
[4]  
FURNEE H, 1997, 3 DIMENSIONAL ANAL H, P85
[5]  
GOLDSTEIN H, 1977, CLASSICAL MECH
[7]   LEG MOTION ANALYSIS DURING GAIT BY MULTIAXIAL ACCELEROMETRY - THEORETICAL FOUNDATIONS AND PRELIMINARY VALIDATIONS [J].
HAYES, WC ;
GRAN, JD ;
NAGURKA, ML ;
FELDMAN, JM ;
OATIS, C .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :283-289
[8]   A randomized, double-blind, placebo-controlled study to evaluate botulinum toxin type A in essential hand tremor [J].
Jankovic, J ;
Schwartz, K ;
Clemence, W ;
Aswad, A ;
Mordaunt, J .
MOVEMENT DISORDERS, 1996, 11 (03) :250-256
[9]   The reliability, validity, and stability of a measure of physical activity in the elderly [J].
Kochersberger, G ;
McConnell, E ;
Kuchibhatla, MN ;
Pieper, C .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (08) :793-795
[10]   TIBIAL SHOCK MEASURED WITH BONE AND SKIN MOUNTED TRANSDUCERS [J].
LAFORTUNE, MA ;
HENNING, E ;
VALIANT, GA .
JOURNAL OF BIOMECHANICS, 1995, 28 (08) :989-993