Comparison of three different kinematic sensor assemblies for locomotion study

被引:26
作者
Giansanti, D [1 ]
Maccioni, G [1 ]
机构
[1] Ist Super Sanita, Dipartimento Tecnol & Salute, I-00161 Rome, Italy
关键词
accelerometer; gyroscopes; simulation; 3D rigid body position and orientation; human movement analysis; accuracy;
D O I
10.1088/0967-3334/26/5/010
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The decrease in the costs of electronic components and devices, conjugated to the advancement of the miniaturization technologies, has promoted a large profusion of the use of motion sensors for human movement analysis in clinics. The errors in the design are numerous, from circuital errors to positioning and orientation errors; a preliminary approach to the problem by means of simulations is necessary. We developed an environment for the simulation of mixed kinematic sensor assemblies with accelerometers and rate gyroscopes; it was tested by means of three different assemblies in the simulation of the trajectory reconstruction. The first assembly was represented by a 6-accelerometer assembly, the second by a 9-accelerometer assembly and the third was based on three rate gyroscopes and three accelerometers. The circuital error, given as an input to the environment, was determined during a bench test, the positioning error was set to P-e = 5 x 10(-4) in and the orientation error to alpha(e) = 6 x 10(-2) deg. Results showed the agreement between estimated and experimental data from the bench test. Simulation results also showed that the errors in trajectory reconstruction in the sagittal plane were lower than 3-4% during 4 s of simulation.
引用
收藏
页码:689 / 705
页数:17
相关论文
共 22 条
[1]   BIOMECHANICAL INVESTIGATION OF WRIST KINEMATICS [J].
ANDREWS, JG ;
YOUM, Y .
JOURNAL OF BIOMECHANICS, 1979, 12 (01) :83-93
[2]  
Ferraris F., 1995, Sensors and Materials, V7, P311
[3]  
FURNEE H, 1997, 3 DIMENSIONAL ANAL H, P85
[4]  
*GAL MOT CONTR INC, DMC 1400 SER MAN
[5]   Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data? [J].
Giansanti, D ;
Macellari, V ;
Maccioni, G ;
Cappozzo, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (04) :476-483
[6]  
GIANSANTI D, 2001, MEASUREMENT KINEMATI
[7]  
GOLDSTEIN H, 1977, CLASSICAL MECH
[9]   A randomized, double-blind, placebo-controlled study to evaluate botulinum toxin type A in essential hand tremor [J].
Jankovic, J ;
Schwartz, K ;
Clemence, W ;
Aswad, A ;
Mordaunt, J .
MOVEMENT DISORDERS, 1996, 11 (03) :250-256
[10]  
KATARIA P, 1998, P BIOM ENG SOC C P, pS133