Retrospective correction of MR intensity inhomogeneity by information minimization

被引:203
作者
Likar, B
Viergever, MA
Pernus, F
机构
[1] Univ Ljubljana, Dept Elect Engn, Ljubljana 1000, Slovenia
[2] Univ Utrecht Hosp, Image Sci Inst, NL-3508 GA Utrecht, Netherlands
关键词
information minimization; intensity inhomogeneity; magnetic resonance imaging; nonuniformity correction; segmentation;
D O I
10.1109/42.974934
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this paper, the problem of retrospective correction of intensity inhomogeneity in magnetic resonance (MR) images is addressed. A novel model-based correction method is proposed, based on the assumption that an image corrupted by intensity inhomogeneity contains more information than the corresponding uncorrupted image. The image degradation process is described by a linear model, consisting of a multiplicative and an additive component which are modeled by a combination of smoothly varying basis functions. The degraded image is corrected by the inverse of the image degradation model. The parameters of this model are optimized such that the information of the corrected image is minimized while the global intensity statistic is preserved. The method was quantitatively evaluated and compared to other methods on a number of simulated and real MR images and proved to be effective, reliable, and computationally attractive. The method can be widely applied to different types of MR images because it solely uses the information that is naturally present in an image, without making assumptions on its spatial and intensity distribution. Besides, the method requires no preprocessing, parameter setting, nor user interaction. Consequently, the proposed method may be a valuable tool in MR image analysis.
引用
收藏
页码:1398 / 1410
页数:13
相关论文
共 38 条
[1]   TECHNICAL NOTE - INTENSITY CORRECTION IN SURFACE-COIL MR IMAGING [J].
AXEL, L ;
COSTANTINI, J ;
LISTERUD, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (02) :418-420
[2]  
Brechbuhler C, 1996, LECT NOTES COMPUT SC, V1131, P141, DOI 10.1007/BFb0046948
[3]   CORRECTION FOR INTENSITY FALLOFF IN SURFACE COIL MAGNETIC-RESONANCE IMAGING [J].
BREY, WW ;
NARAYANA, PA .
MEDICAL PHYSICS, 1988, 15 (02) :241-245
[4]   Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correction [J].
Brinkmann, BH ;
Manduca, A ;
Robb, RA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (02) :161-171
[5]  
Cocosco CA., 1997, NEUROIMAGE, V5, pS425, DOI DOI 10.1016/S1053-8119(97)80018-3
[6]   Design and construction of a realistic digital brain phantom [J].
Collins, DL ;
Zijdenbos, AP ;
Kollokian, V ;
Sled, JG ;
Kabani, NJ ;
Holmes, CJ ;
Evans, AC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (03) :463-468
[7]   IMAGE NONUNIFORMITY IN MAGNETIC-RESONANCE-IMAGING - ITS MAGNITUDE AND METHODS FOR ITS CORRECTION [J].
CONDON, BR ;
PATTERSON, J ;
WYPER, D ;
JENKINS, PA ;
HADLEY, DM .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (709) :83-87
[8]   CORRECTION OF INTENSITY VARIATIONS IN MR-IMAGES FOR COMPUTER-AIDED TISSUE CLASSIFICATION [J].
DAWANT, BM ;
ZIJDENBOS, AP ;
MARGOLIN, RA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) :770-781
[9]   VOLUMETRIC ANALYSES OF CENTRAL-NERVOUS-SYSTEM NEOPLASM BASED ON MRI [J].
FILIPEK, PA ;
KENNEDY, DN ;
CAVINESS, VS .
PEDIATRIC NEUROLOGY, 1991, 7 (05) :347-351
[10]   Estimating the bias field of MR images [J].
Guillemaud, R ;
Brady, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (03) :238-251