MEG source localization under multiple constraints: An extended Bayesian framework

被引:132
作者
Mattout, J
Phillips, C
Penny, WD
Rugg, MD
Friston, KJ
机构
[1] Wellcome Dept Imaging Neurosci, London WC1N 3BG, England
[2] Ctr Rech Cyclotron, Liege, Belgium
[3] Ctr Neurobiol Learning & Memory, Irvine, CA 92697 USA
基金
英国惠康基金;
关键词
MEG; inverse problem; multiple constraints; empirical Bayes; restricted maximum likelihood (ReML); model selection; ROC; Multivariate Source Prelocalization (MSP);
D O I
10.1016/j.neuroimage.2005.10.037
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
To use Electroencephalography (EEG) and Magnetoencephalography (MEG) as functional brain 3D imaging techniques, identifiable distributed source models are required. The reconstruction of EEG/MEG sources rests on inverting these models and is ill-posed because the solution does not depend continuously on the data and there is no unique solution in the absence of prior in formation or constraints. We have described a general framework that can account for several priors in a common inverse solution. An empirical Bayesian framework based on hierarchical linear models was proposed for the analysis of functional neuroimaging data [Friston, K., Penny, W, Phillips, C., Kiebel, S., Hinton, G., Ashburner, J., 2002. Classical and BaN inference in neuroitnaging: theory. Neurolmage 16, 465-483] and was evaluated recently in the context of EEG [Phillips, C., Mattout, J., Rugg, M.D., Maquet, P., Friston, K., 2005. An empirical Bayesian solution to the source reconstruction problem in EEG. Neurolmage 24, 997-1011]. The approach consists of estimating the expected source distribution and its conditional variance that is constrained by an empirically determined mixture of prior variance components. Estimation uses Expectation-Maximization (EM) to give the Restricted Maximum Likelihood (ReML) estimate of the variance components (in terms of hyperparameters) and the Maximum A Posteriori (MAP) estimate of the source parameters. In this paper, we extend the framework to compare different combinations of priors, using a second level of inference based on Bayesian model selection. Using Monte- Carlo simulations, ReML is first compared to a classic Weighted Minimum Norm (WMN) solution under a single constraint. Then, the ReML estimates are evaluated using various combinations of priors. Both standard criterion and ROC-based measures were used to assess localization and detection performance. The empirical Bayes approach proved useful as: (1) ReML was significantly better than WMN for single priors; (2) valid location priors improved ReML source localization; (3) invalid location priors did not significantly impair performance. Finally, we show how model selection, using the log-evidence, can be used to select file best combination of priors. This enables a global strategy for multiple prior-based regularization of the MEG/EEG source reconstruction. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:753 / 767
页数:15
相关论文
共 46 条
[11]   IMPROVED LOCALIZATION OF CORTICAL ACTIVITY BY COMBINING EEG AND MEG WITH MRI CORTICAL SURFACE RECONSTRUCTION - A LINEAR-APPROACH [J].
DALE, AM ;
SERENO, MI .
JOURNAL OF COGNITIVE NEUROSCIENCE, 1993, 5 (02) :162-176
[12]   Assessing the relevance of fMRI-based prior in the EEG inverse problem:: A Bayesian model comparison approach [J].
Daunizeau, J ;
Grova, C ;
Mattout, J ;
Marrelec, G ;
Clonda, D ;
Goulard, B ;
Pélégrini-Issac, M ;
Lina, JM ;
Benali, H .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2005, 53 (09) :3461-3472
[13]   Rapidly recomputable EEG forward models for realistic head shapes [J].
Ermer, JJ ;
Mosher, JC ;
Baillet, S ;
Leahy, RM .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04) :1265-1281
[14]  
FRISTON K, IN PRESS HUM BRAIN M
[15]   Classical and Bayesian inference in neuroimaging: Theory [J].
Friston, KJ ;
Penny, W ;
Phillips, C ;
Kiebel, S ;
Hinton, G ;
Ashburner, J .
NEUROIMAGE, 2002, 16 (02) :465-483
[16]   GENERALIZED CROSS-VALIDATION AS A METHOD FOR CHOOSING A GOOD RIDGE PARAMETER [J].
GOLUB, GH ;
HEATH, M ;
WAHBA, G .
TECHNOMETRICS, 1979, 21 (02) :215-223
[17]   NEUROMAGNETIC SOURCE IMAGING WITH FOCUSS - A RECURSIVE WEIGHTED MINIMUM NORM ALGORITHM [J].
GORODNITSKY, IF ;
GEORGE, JS ;
RAO, BD .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1995, 95 (04) :231-251
[18]   INTERPRETING MAGNETIC-FIELDS OF THE BRAIN - MINIMUM NORM ESTIMATES [J].
HAMALAINEN, MS ;
ILMONIEMI, RJ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (01) :35-42
[19]   ANALYSIS OF DISCRETE ILL-POSED PROBLEMS BY MEANS OF THE L-CURVE [J].
HANSEN, PC .
SIAM REVIEW, 1992, 34 (04) :561-580
[20]  
HARVILLE DA, 1977, J AM STAT ASSOC, V72, P320, DOI 10.2307/2286796