Sevoflurane requirements during ambulatory surgery:: a clinical study with and without AEP-index guidance

被引:18
作者
Assareh, H
Anderson, RE
Uusijärvi, J
Jakobsson, J
机构
[1] Sabbatsbergs Hosp, Dept Anesthesia, S-11324 Stockholm, Sweden
[2] Sabbatsbergs Hosp, Dept Orthopaed, S-11324 Stockholm, Sweden
[3] Karolinska Hosp, Dept Cardiothorac Anesthet & Intens Care, S-10401 Stockholm, Sweden
关键词
anesthesia; general anesthetics; sevoflurane analgesics; fentanyl; evoked potentials; auditory surgery; ambulatory;
D O I
10.1034/j.1399-6576.2002.460504.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Several monitors have been developed to measure anesthetic depth. The auditory evoked response uses an auditory signal to actively test the level of brain activity. The aim of the present study was to determine whether sevoflurane titration with A-line auditory guidance from the evoked potential monitor would reduce gas consumption and improve recovery times. Methods: Patients (n=60, aged 18-65years) undergoing elective knee arthroscopy were randomized to titrate the main anesthetic sevoflurane with O-2:N2O(1:2), either clinically (30 patients) or in combination with a target auditory evoked potential index of 30 5 (30 patients) using the A-line monitor (version 1.4, Danmeter A/S; Odense, Denmark). Induction was supplemented with fentanyl, and randomized to 0.05, 0.10 and 0.15mg immediately before propofol (10 in each group). Sevoflurane consumption and emergence times were the primary and secondary study end-points. Results: Guidance from the A-line monitor did not reduce the sevoflurane consumption time or the emergence, regardless of the fentanyl dose. However, it did reduce the time from the recovery room to discharge eligibility (P<0.05). Sevoflurane consumption decreased inversely with the fentanyl dose (P<0.01), with no impact on emergence times. Conclusion: The auditory evoked potential index provided by the A-line monitor does not decrease sevoflurane consumption or emergence times for ambulatory knee arthroscopy.
引用
收藏
页码:495 / 499
页数:5
相关论文
共 23 条
[1]   Being awake intermittently during propofol-induced hypnosis:: A study of BIS, explicit and implicit memory [J].
Barr, G ;
Anderson, RE ;
Öwall, A ;
Jakobsson, JG .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (07) :834-838
[2]   A study of bispectral analysis and auditory evoked potential indices during propofol-induced hypnosis in volunteers - The effect of an episode of wakefulness on explicit and implicit memory [J].
Barr, G ;
Anderson, RE ;
Jakobsson, JG .
ANAESTHESIA, 2001, 56 (09) :888-893
[3]   Midlatency auditory evoked potentials as indicators of perceptual processing during general anaesthesia [J].
DeBeer, NAM ;
vanHooff, JC ;
Brunia, CHM ;
Cluitmans, PJM ;
Korsten, HHM ;
Beneken, JEW .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (05) :617-624
[4]  
Doolke A, 2001, Ambul Surg, V9, P95, DOI 10.1016/S0966-6532(01)00101-9
[5]   RELATIONSHIP BETWEEN LOWER ESOPHAGEAL CONTRACTILITY, CLINICAL SIGNS AND HALOTHANE CONCENTRATION DURING GENERAL-ANESTHESIA AND SURGERY IN MAN [J].
EVANS, JM ;
BITHELL, JF ;
VLACHONIKOLIS, IG .
BRITISH JOURNAL OF ANAESTHESIA, 1987, 59 (11) :1346-1355
[6]   Comparison of bispectral EEG analysis and auditory evoked potentials for monitoring depth of anaesthesia during propofol anaesthesia [J].
Gajraj, RJ ;
Doi, M ;
Mantzaridis, H ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (05) :672-678
[7]   Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia [J].
Gan, TJ ;
Glass, PS ;
Windsor, A ;
Payne, F ;
Rosow, C ;
Sebel, P ;
Manberg, P ;
Howell, S ;
Sanderson, I ;
Ray, J ;
Elidrissi, C ;
Wilkes, N ;
Calhoun, P ;
Connors, P ;
Alfille, P ;
Shapiro, L ;
Denman, W ;
Dershwitz, M ;
Clifford, J ;
Embree, P ;
Sigl, J .
ANESTHESIOLOGY, 1997, 87 (04) :808-815
[8]   EFFECT OF ISOFLURANE ON THE AUDITORY EVOKED-RESPONSE IN MAN [J].
HENEGHAN, CPH ;
THORNTON, C ;
NAVARATNARAJAH, M ;
JONES, JG .
BRITISH JOURNAL OF ANAESTHESIA, 1987, 59 (03) :277-282
[9]   The sevoflurane-sparing effect of nitrous oxide: a clinical study [J].
Jakobsson, J ;
Heidvall, M ;
Davidson, S .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1999, 43 (04) :411-414
[10]  
Jensen EW, 1998, MED ENG PHYS, V20, P722, DOI 10.1016/S1350-4533(98)00089-7