Evaluation of different solid-phase traps for automated collection and clean-up in the analysis of multiple pesticides in fruits and vegetables after supercritical fluid extraction

被引:55
作者
Lehotay, SJ [1 ]
ValverdeGarcia, A [1 ]
机构
[1] UNIV ALMERIA,PESTICIDE RESIDUE RES GRP,FAC SCI,ALMERIA 04071,SPAIN
关键词
fruits; vegetables; food analysis; multiresidue analysis; sample preparation; supercritical fluid extraction; solid-phase extraction; pesticides;
D O I
10.1016/S0021-9673(96)00846-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study was designed to determine which combination of sorbent-trap and elution solvent provided the most efficient automated method of collection in supercritical fluid extraction (SFE), elution of analytes, and clean-up of orange, sweet potato and green bean extracts for analysis of 56 diverse pesticides using GC-ion-trap MS. The solid-phase traps evaluated consisted of octyldecylsilane (ODS), diol, Tenax and Porapak-Q, and the elution solvents compared were acetone, ethyl acetate, acetonitrile and methanol. SFE collection by bubbling into each organic solvent was also compared. Recoveries, elution volumes, limits of detection and clean-up aspects were determined for each combination of commodity, trap and solvent tested. High trapping efficiencies were achieved in each case, and acetone usually eluted the pesticides in the least volume (<1 ml) from the traps. The few matrix components that interfered in GC-ion-trap MS continued to interfere in all trap/solvent pairs, and limits of detection were independent of trap/solvent combination. The use of the ODS trap and acetone elution solvent gave the most consistently high recoveries of the traps and solvents tested.
引用
收藏
页码:69 / 84
页数:16
相关论文
共 34 条
  • [1] COMPARISON OF THE EFFICIENCY OF DIFFERENT GLC MULTI-RESIDUE METHODS ON CROPS CONTAINING PESTICIDE-RESIDUES
    ANDERSSON, A
    PALSHEDEN, H
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (06): : 365 - 367
  • [2] ANDERSSON A, COMMUNICATION
  • [3] CRYOGENICALLY COOLED ADSORBENT TRAP FOR OFF-LINE SUPERCRITICAL FLUID EXTRACTION
    ASHRAFKHORASSANI, M
    HOUCK, RK
    LEVY, JM
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1992, 30 (09) : 361 - 366
  • [4] SOLID-PHASE TRAPPING OF POLYCHLORINATED-BIPHENYLS IN SUPERCRITICAL-FLUID EXTRACTION
    BOWADT, S
    JOHANSSON, B
    PELUSIO, F
    LARSEN, BR
    ROVIDA, C
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 662 (02) : 424 - 433
  • [5] MULTIRESIDUE PESTICIDE ANALYSIS BY ION-TRAP MASS-SPECTROMETRY
    CAIRNS, T
    CHIU, KS
    NAVARRO, D
    SIEGMUND, E
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (11) : 971 - 988
  • [6] ECKARD PR, 1996, J HIGH RES CHROMATOG, V19, P117
  • [7] Fillion J, 1995, J AOAC INT, V78, P1252
  • [8] SUPERCRITICAL FLUID-BASED CLEANUP TECHNIQUE FOR THE SEPARATION OF ORGANOCHLORINE PESTICIDES FROM FATS
    FRANCE, JE
    KING, JW
    SNYDER, JM
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1991, 39 (10) : 1871 - 1874
  • [9] Holland P. T., 1992, Emerging strategies for pesticide analysis., P71
  • [10] HOPPER ML, 1991, J ASSOC OFF ANA CHEM, V74, P661