Frequency of silent myocardial ischemia following coronary stenting

被引:6
作者
Kathiresan, S
Jordan, MK
Gimelli, G
Lopez-Cuellar, J
Madhi, N
Jang, IK
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Med, Boston, MA 02114 USA
关键词
D O I
10.1016/S0002-9149(99)00469-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To detect silent myocardial ischemia, 12-lead continuous electrocardiographic monitoring was performed in patients undergoing 1-vessel coronary stenting. Despite successful angiographic results, one third of the patients experienced silent myocardial ischemia during the postprocedural period.
引用
收藏
页码:930 / +
页数:4
相关论文
共 11 条
[1]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[2]   SILENT ISCHEMIA AS A MARKER FOR EARLY UNFAVORABLE OUTCOMES IN PATIENTS WITH UNSTABLE ANGINA [J].
GOTTLIEB, SO ;
WEISFELDT, ML ;
OUYANG, P ;
MELLITS, ED ;
GERSTENBLITH, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1986, 314 (19) :1214-1219
[3]   COMPARISON OF THE EFFECT OF HEPARIN AND ASPIRIN VERSUS ASPIRIN ALONE ON TRANSIENT MYOCARDIAL-ISCHEMIA AND IN-HOSPITAL PROGNOSIS IN PATIENTS WITH UNSTABLE ANGINA [J].
HOLDRIGHT, D ;
PATEL, D ;
CUNNINGHAM, D ;
THOMAS, R ;
HUBBARD, W ;
HENDRY, G ;
SUTTON, G ;
FOX, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (01) :39-45
[4]   Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: A combined intravascular ultrasound Doppler flow and imaging study [J].
Kern, MJ ;
Dupouy, P ;
Drury, JH ;
Aguirre, FV ;
Aptecar, E ;
Bach, RG ;
Caracciolo, EA ;
Donohue, TJ ;
Rande, JLD ;
Geschwind, HJ ;
Mechem, CJ ;
Kane, G ;
Teiger, E ;
Wolford, TL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (07) :1520-1527
[5]   Reduction of recurrent ischemia with abciximab during continuous ECG-ischemia monitoring in patients with unstable angina refractory to standard treatment (CAPTURE) [J].
Klootwijk, P ;
Meij, S ;
Melkert, R ;
Lenderink, T ;
Simoons, ML .
CIRCULATION, 1998, 98 (14) :1358-1364
[6]  
Krucoff MW, 1987, SILENT ISCHEMIA CURR, P140
[7]   PROGNOSTIC-SIGNIFICANCE OF SILENT-MYOCARDIAL-ISCHEMIA IN PATIENTS WITH UNSTABLE ANGINA [J].
NADEMANEE, K ;
INTARACHOT, V ;
JOSEPHSON, MA ;
RIEDERS, D ;
MODY, FV ;
SINGH, BN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (01) :1-9
[8]   Long-term prognosis in unstable angina - The importance of early risk stratification using continuous ST segment monitoring [J].
Patel, DJ ;
Knight, CJ ;
Holdright, DR ;
Mulcahy, D ;
Clarke, D ;
Wright, C ;
Purcell, H ;
Fox, KM .
EUROPEAN HEART JOURNAL, 1998, 19 (02) :240-249
[9]  
Patel DJ, 1997, CIRCULATION, V95, P1185
[10]   A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SERRUYS, PW ;
DEJAEGERE, P ;
KIEMENEIJ, F ;
MACAYA, C ;
RUTSCH, W ;
HEYNDRICKX, G ;
EMANUELSSON, H ;
MARCO, J ;
LEGRAND, V ;
MATERNE, P ;
BELARDI, J ;
SIGWART, U ;
COLOMBO, A ;
GOY, JJ ;
VANDENHEUVEL, P ;
DELCAN, J ;
MOREL, MA .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :489-495