Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: A combined intravascular ultrasound Doppler flow and imaging study

被引:92
作者
Kern, MJ
Dupouy, P
Drury, JH
Aguirre, FV
Aptecar, E
Bach, RG
Caracciolo, EA
Donohue, TJ
Rande, JLD
Geschwind, HJ
Mechem, CJ
Kane, G
Teiger, E
Wolford, TL
机构
[1] ST LOUIS UNIV, DIV CARDIOL, DEPT INTERNAL MED, ST LOUIS, FRANCE
[2] UNIV PARIS 12, HOP HENRI MONDOR, UNITE HEMODYNAM & CARDIOL INTERVENT, SERV EXPLORAT FONCT, F-94010 CRETEIL, FRANCE
关键词
D O I
10.1016/S0735-1097(97)00082-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study sought to examine the mechanism of increasing coronary flow reserve after balloon angioplasty and stenting. Background. Coronary vasodilatory reserve (CVR) does not improve after percutaneous transluminal coronary angioplasty in greater than or equal to 50% of patients, postulated to be due to impaired microvascular circulation or inadequate lumen expansion despite adequate angiographic results. Methods. To demonstrate the role of coronary lumen expansion, serial coronary how velocity (0.014-in. Doppler guide wire) was measured in 42 patients before and after balloon angioplasty and again after stent placement. A subset (n = 17) also underwent intravascular ultrasound (TWS) imaging of the target sites after angioplasty and stenting. CVR (velocity) was computed as the ratio of adenosine-induced maximal hyperemic to basal average peak velocity. Results. The percent diameter stenosis decreased from (mean +/- SD) 84 +/- 13% to 37 +/- 18% after angioplasty and to 8 +/- 8% after stenting (both p < 0.05). CVR was minimally changed from 1.70 +/- 0.79 at baseline to 1.89 +/- 0.56 (p = NS) after angioplasty but increased to 2.49 +/- 0.68 after stent placement (p < 0.01 vs. before and after angioplasty). IVUS lumen cross sectional area was significantly larger after stenting than after angioplasty (8.39 +/- 2.09 vs. 5.10 +/- 2.03 mm(2), p < 0.05). Anatomic variables were related to increasing coronary Row velocity reserve (CVR vs. IVUS lumen area: r = 0.47, p < 0.005; CVR vs. quantitative coronary angiographic percent area stenosis: r = 0.58, p < 0.0001). Conclusions. In most cases, increases in CVR were associated with increases in coronary lumen cross-sectional area. These data suggest that impaired CVR after angioplasty is often related to the degree of residual narrowing, which at times may not be appreciated by angiography. A physiologically complemented approach to balloon angioplasty may improve procedural outcome. (C) 1997 by the American College of Cardiology.
引用
收藏
页码:1520 / 1527
页数:8
相关论文
共 40 条
[1]   Coronary Vasodilator Reserve in Untreated and Treated Hypertensive Patients With and Without Left Ventricular Hypertrophy [J].
Antony, Isabelle ;
Nitenberg, Alain ;
Foult, Jean-Marc ;
Aptecar, Eduardo .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) :514-520
[2]   RELEASE OF ATHEROSCLEROTIC DEBRIS AFTER TRANS-LUMINAL ANGIOPLASTY [J].
BLOCK, PC ;
ELMER, D ;
FALLON, JT .
CIRCULATION, 1982, 65 (05) :950-952
[3]   COMBINED INTRAVASCULAR ULTRASOUND ANGIOPLASTY BALLOON CATHETER - INITIAL USE DURING PTCA [J].
CACCHIONE, JG ;
REDDY, K ;
RICHARDS, F ;
SHEEHAN, H ;
HODGSON, JM .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 24 (02) :99-101
[4]   ANGINA CAUSED BY REDUCED VASODILATOR RESERVE OF THE SMALL CORONARY-ARTERIES [J].
CANNON, RO ;
WATSON, RM ;
ROSING, DR ;
EPSTEIN, SE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 1 (06) :1359-1373
[5]   MEASUREMENT OF VOLUMETRIC CORONARY BLOOD-FLOW BY SIMULTANEOUS INTRAVASCULAR 2-DIMENSIONAL AND DOPPLER ULTRASOUND - VALIDATION IN AN ANIMAL-MODEL [J].
CHOU, TM ;
SUDHIR, K ;
IWANAGA, S ;
CHATTERJEE, K ;
YOCK, PG .
AMERICAN HEART JOURNAL, 1994, 128 (02) :237-243
[6]   QUANTITATIVE CORONARY ANGIOGRAPHY TO MEASURE PROGRESSION AND REGRESSION OF CORONARY ATHEROSCLEROSIS - VALUE, LIMITATIONS, AND IMPLICATIONS FOR CLINICAL-TRIALS [J].
DEFEYTER, PJ ;
SERRUYS, PW ;
DAVIES, MJ ;
RICHARDSON, P ;
LUBSEN, J ;
OLIVER, MF .
CIRCULATION, 1991, 84 (01) :412-423
[7]   THE ANGLE OF INCIDENCE OF THE ULTRASONIC BEAM - A CRITICAL FACTOR FOR THE IMAGE QUALITY IN INTRAVASCULAR ULTRASONOGRAPHY [J].
DIMARIO, C ;
MADRETSMA, S ;
LINKER, D ;
THE, SHK ;
BOM, N ;
SERRUYS, PW ;
GUSSENHOVEN, EJ ;
ROELANDT, JRTC .
AMERICAN HEART JOURNAL, 1993, 125 (02) :442-448
[8]  
DIMARIO C, 1995, AM J CARDIOL, V75, P1177
[9]  
DIMARIO C, 1994, TXB INTERVENTIONAL C, P768
[10]   Assessing the Hemodynamic Significance of Coronary Artery Stenoses: Analysis of Translesional Pressure-Flow Velocity Relations in Patients [J].
Donohue, Thomas J. ;
Kern, Morton J. ;
Aguirre, Frank V. ;
Bach, Richard G. ;
Wolford, Thomas ;
Bell, Calvin A. ;
Segal, Jerome .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) :449-458