A rapid, sensitive and automated method for detection of Salmonella species in foods using AG-9600 AmpliSensor analyzer

被引:24
作者
Chen, S
Yee, A
Griffiths, M
Wu, KY
Wang, CN
Rahn, K
DeGrandis, SA
机构
[1] ONTARIO MINIST AGR FOOD & RURAL AFFAIRS,AGR & FOOD LAB SERV CTR,GUELPH,ON N1H 8J7,CANADA
[2] UNIV GUELPH,DEPT FOOD SCI,GUELPH,ON N1G 2W1,CANADA
[3] BIOTRON TECHNOL CORP,LOWELL,MA
[4] AGR & AGRI FOOD CANADA,ANIM HLTH LABS,GUELPH,ON,CANADA
关键词
D O I
10.1046/j.1365-2672.1997.00226.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The AG-9600 AmpliSensor Analyzer is an automated fluorescence-based system for detection of polymerase chain reaction (PCR) produces, The principle of the AmpliSensor PCR assay involves amplification-mediated disruption of a fluorogenic DNA signal duplex (AmpliSensor) that is homologous to a target sequence within a 284-bp amplified fragment of the Salmonella invA gene, Since the assay is homogenous, the data can be obtained by direct measurement of fluorescence of the amplification mixture, The accumulation of the amplified product, reflected by the fluorescence index, is monitored cycle by cycle by the AG-9600 Analyzer. The detection limit of the assay was less than 2 colony-forming units (cfu) per PCR reaction using a pure culture of Salmonella typhimurium. In post-spiking experiments in which Salmonella was added to the overnight pre-enriched samples (chicken carcass rinses, ground beef, ground pork and raw milk), the detection limit of the assay was 2-6 cfu per PCR reaction. In pre-spiking experiments in which Salmonella was added to the samples prior to overnight pre-enrichment, the detection limit was less than 3 cfu per 25 g or 25 ml of food, The assay was up to 2 orders of magnitude more sensitive than detection by ethidium bromide-stained agarose gel electrophoresis. To further evaluate assay performance, 54 naturally contaminated chicken carcass rinses, 65 raw milk and six ground pork samples were tested in the study. Thirty-eight Salmonella-positive samples confirmed by the Modified Semi-solid Rappaport-Vassiliadis (MSRV) culture assay were found positive using the AmpliSensor assay. Two chicken carcass rinses found positive using the assay were MSRV-negative. In addition, relative quantification using the AmpliSensor assay was linear up to 3 logs of initial target concentration in artificially contaminated food samples.
引用
收藏
页码:314 / 321
页数:8
相关论文
共 28 条
  • [1] [Anonymous], 1984, OFFICIAL METHODS ANA, V14th
  • [2] RAPID AND ALTERNATIVE METHODS FOR THE DETECTION OF SALMONELLAS IN FOODS
    BLACKBURN, CD
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1993, 75 (03): : 199 - 214
  • [3] FLUORESCENT DETECTION-POLYMERASE CHAIN-REACTION (FD-PCR) ASSAY ON MICROWELL PLATES AS A SCREENING-TEST FOR SALMONELLAS IN FOODS
    CANO, RJ
    RASMUSSEN, SR
    FRAGA, GS
    PALOMARES, JC
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1993, 75 (03): : 247 - 253
  • [4] CHEN S, 1995, 45 ANN CAN SOC MICR
  • [5] CURIALE MS, 1990, J ASSOC OFF ANA CHEM, V73, P248
  • [6] DNA-BASED DIAGNOSTIC-TESTS FOR SALMONELLA SPECIES TARGETING AGFA, THE STRUCTURAL GENE FOR THIN, AGGREGATIVE FIMBRIAE
    DORAN, JL
    COLLINSON, SK
    BURIAN, J
    SARLOS, G
    TODD, ECD
    MUNRO, CK
    KAY, CM
    BANSER, PA
    PETERKIN, PI
    KAY, WW
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (09) : 2263 - 2273
  • [7] RAPID DETECTION OF SALMONELLA IN FOODS USING EF-18 AGAR IN CONJUNCTION WITH THE HYDROPHOBIC GRID MEMBRANE-FILTER
    ENTIS, P
    BOLESZCZUK, P
    [J]. JOURNAL OF FOOD PROTECTION, 1991, 54 (12) : 930 - 934
  • [8] GALAN JE, 1991, INFECT IMMUN, V59, P2901
  • [9] GIBSON DM, 1992, J AOAC INT, V75, P293
  • [10] THE DETECTION OF FOODBORNE PATHOGENS BY THE POLYMERASE CHAIN-REACTION (PCR)
    HARRIS, LJ
    GRIFFITHS, MW
    [J]. FOOD RESEARCH INTERNATIONAL, 1992, 25 (06) : 457 - 469