Simple Coupling of Gas Chromatography to Electrospray Ionization Mass Spectrometry

被引:28
作者
Brenner, Nina [1 ]
Haapala, Markus [1 ]
Vuorensola, Katariina [1 ]
Kostiainen, Risto [1 ]
机构
[1] Univ Helsinki, Fac Pharm, Div Pharmaceut Chem, FI-00014 Helsinki, Finland
关键词
D O I
10.1021/ac801406t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method for direct coupling of gas chromatography (GC) with electrospray ionization mass spectrometry (ESI/MS) has been developed. The outlet of the GC capillary column was placed between the ESI needle and the atmospheric pressure ionization (API) source of a mass spectrometer. The ionization occurs via dissolution of neutral compounds into the charged ESI droplet followed by ion evaporation or via a gas-phase proton transfer reaction between a protonated solvent molecule and an analyte. The mass spectra of organic volatile compounds showed abundant protonated molecules with little fragmentation, being very similar to those produced by normal liquid ESI. The quantitative performance of the system was evaluated by determining the limit of detection (LOD), linearity (r(2)), and repeatability (RSD). The GC-ESI/MS method was shown to be stable, providing high sensitivity and good quantitative performance.
引用
收藏
页码:8334 / 8339
页数:6
相关论文
共 32 条
[1]   Rapid in vivo fingerprinting of nonvolatile compounds in breath by extractive electrospray ionization quadrupole time-of-flight mass spectrometry [J].
Chen, Huanwen ;
Wortmann, Arno ;
Zhang, Weihua ;
Zenobi, Renato .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (04) :580-583
[2]   Extractive electrospray ionization for direct analysis of undiluted urine, milk and other complex mixtures without sample preparation [J].
Chen, HW ;
Venter, A ;
Cooks, RG .
CHEMICAL COMMUNICATIONS, 2006, (19) :2042-2044
[3]   Influence of the eluent composition on the ionization efficiency for morphine of pneumatically assisted electrospray, atmospheric-pressure chemical ionization and sonic spray [J].
Dams, R ;
Benijts, T ;
Günther, W ;
Lambert, W ;
De Leenheer, A .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (11) :1072-1077
[4]   COMPARISON OF POSITIVE-IONS FORMED IN NICKEL-63 AND CORONA DISCHARGE ION SOURCES USING NITROGEN, ARGON, ISOBUTANE, AMMONIA AND NITRIC-OXIDE AS REAGENTS IN ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY [J].
DZIDIC, I ;
CARROLL, DI ;
STILLWELL, RN ;
HORNING, EC .
ANALYTICAL CHEMISTRY, 1976, 48 (12) :1763-1768
[5]   A microfabricated nebulizer for liquid vaporization in chemical analysis [J].
Franssila, Sami ;
Marttila, Seppo ;
Kolari, Kai ;
Ostman, Pekka ;
Kotiaho, Tapio ;
Kostiainen, Risto ;
Lehtiniemi, Reijo ;
Fager, Carl-Magnus ;
Manninen, Jorma .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2006, 15 (05) :1251-1259
[6]   Microchip for combining gas chromatography or capillary liquid chromatography with atmospheric pressure photoionization-mass spectrometry [J].
Haapala, Markus ;
Luosujarvi, Laura ;
Saarela, Ville ;
Kotiaho, Tapio ;
Ketola, Raimo A. ;
Franssila, Sami ;
Kostiainen, Risto .
ANALYTICAL CHEMISTRY, 2007, 79 (13) :4994-4999
[7]   Characterization of synthetic polymers by electrospray-assisted pyrolysis ionization-mass spectrometry [J].
Hsu, HJ ;
Kuo, TL ;
Wu, SH ;
Oung, JH ;
Shiea, J .
ANALYTICAL CHEMISTRY, 2005, 77 (23) :7744-7749
[8]   Using electrospray-assisted pyrolysis ionization/mass spectrometry for the rapid characterization of trace polar components in crude oil, amber, humic substances, and rubber samples [J].
Hsu, Hsiu-Jung ;
Oung, Jung-Nan ;
Kuo, Tseng-Long ;
Wu, Suh-Huey ;
Shiea, Jentaie .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (03) :375-384
[9]  
Kinouchi T., 1990, Journal of High Resolution Chromatography and Chromatography Communications, V13, P281, DOI 10.1002/jhrc.1240130415
[10]   CONFIRMATION OF HEPTACHLOR EPOXIDE AND OCTACHLOR EPOXIDE IN MILK VIA FUSED-SILICA GAS-CHROMATOGRAPHY NEGATIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
KORFMACHER, WA ;
RUSHING, LG ;
SIITONEN, PH ;
BRANSCOMB, CJ ;
HOLDER, CL .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (06) :332-336