Characterization of synthetic polymers by electrospray-assisted pyrolysis ionization-mass spectrometry

被引:21
作者
Hsu, HJ
Kuo, TL
Wu, SH
Oung, JH
Shiea, J [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
[2] Chinese Petr Co, Explorat & Dev Res Inst, Miaoli, Taiwan
[3] Chinese Petr Co, Explorat & Prod Business Div, Miaoli, Taiwan
关键词
D O I
10.1021/ac051116m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid characterization of synthetic polymers based on the differences in the appearance of the polar pyrolysate ions was achieved by electrospray-assisted pyrolysis ionization-mass spectrometry. The pyrolytical products produced by a commercial Curie point pyroprobe were conducted to the tip of a capillary, where charged methanol droplets were generated continuously by electrospray. Polar components in the pyrolysates may react directly with the protonated methanol ions or fuse with the charged methanol droplets; electrospray ionization proceeds from the fused droplets to generate protonated analyte ions. The mass spectra obtained through this approach were used to rapidly distinguish the polymer standards that differ in the nature of building units, degrees of polymerization, and copolymerization coefficients.
引用
收藏
页码:7744 / 7749
页数:6
相关论文
共 35 条
[1]   IDENTIFICATION OF BACTERIA USING MASS-SPECTROMETRY [J].
ANHALT, JP ;
FENSELAU, C .
ANALYTICAL CHEMISTRY, 1975, 47 (02) :219-225
[2]   Detecting large biomolecules from high-salt solutions by fused-droplet electrospray ionization mass spectrometry [J].
Chang, DY ;
Lee, CC ;
Shiea, J .
ANALYTICAL CHEMISTRY, 2002, 74 (11) :2465-2469
[3]   A COMPARISON OF PRODUCTS FROM AN AIR ATMOSPHERE TUBE FURNACE WITH A VACUUM CURIE-POINT PYROLYZER - IMPLICATIONS FOR BIODETECTION [J].
DELUCA, SJ ;
VOORHEES, KJ .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1993, 24 (03) :211-225
[4]   CONSIDERATIONS OF PHYSICOCHEMICAL PHENOMENA IN COAL PROCESSING [J].
DERBYSHIRE, F ;
DAVIS, A ;
LIN, R .
ENERGY & FUELS, 1989, 3 (04) :431-437
[5]  
ELIAS HG, 1997, INTRO POLYM SCI, P107
[6]  
EVANS N, 1980, ADV MASS SPECTROM A, V8, P103
[7]   Pyrolysis gas chromatography mass spectrometry investigation of a thermally cured polymer [J].
Galipo, RC ;
Egan, WJ ;
Aust, JF ;
Myrick, ML ;
Morgan, SL .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1998, 45 (01) :23-40
[8]   THE USE OF PYROLYSIS MASS-SPECTROMETRY TO DETECT THE FIMBRIAL ADHESIVE ANTIGEN F41 FROM ESCHERICHIA-COLI HB101 (PSLM204) [J].
GOODACRE, R ;
BERKELEY, RCW ;
BERINGER, JE .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1991, 22 (1-2) :19-28
[9]  
GUTTERIDGE CS, 1987, METHOD MICROBIOL, V19, P227
[10]   ANALYSIS OF INSITU METHYLATED MICROBIAL FATTY-ACID CONSTITUENTS BY CURIE-POINT PYROLYSIS-GAS CHROMATOGRAPHY-MASS SPECTROMETRY [J].
HOLZER, G ;
BOURNE, TF ;
BERTSCH, W .