Detecting large biomolecules from high-salt solutions by fused-droplet electrospray ionization mass spectrometry

被引:107
作者
Chang, DY [1 ]
Lee, CC [1 ]
Shiea, J [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
关键词
D O I
10.1021/ac010788j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel fused-droplet electrospray ionization (FD-ESI) source was developed to generate peptide and protein ions. The sample solution was first ultrasonically nebulized to form fine aerosols. The aerosols were then purged into a glass reaction chamber via nitrogen. Charged methanol droplets were continuously generated through electrospraying the acidic methanol solution from a capillary, which was located at the center of the reaction chamber. As the sample aerosols entered the reaction chamber, they fused with the charged methanol droplets from which electrospray proceeded continuously. The mass spectra of peptide and protein that FD-ESI-MS produced were practically identical to those that conventional ESI-MS produced. However, FD-ESI-MS resulted in an extremely high salt tolerance. Cytochrome c ions were detected in the solutions that contained 10% (w/w; 1.709 M) NaCl or 2.5% (425 mM) NaH2PO4. As with those obtained from the solution that lacked NaCl and NaH2PO4, the width of cytochrome c ion peaks remained nearly unchanged.
引用
收藏
页码:2465 / 2469
页数:5
相关论文
共 26 条
[1]  
Amad MH, 2000, J MASS SPECTROM, V35, P784, DOI 10.1002/1096-9888(200007)35:7<784::AID-JMS17>3.0.CO
[2]  
2-Q
[3]  
BUDAVARI S, 1989, MERCK INDEX, P5868
[4]   CHARGE-STATE REDUCTION OF OLIGONUCLEOTIDE NEGATIVE-IONS FROM ELECTROSPRAY-IONIZATION [J].
CHENG, XH ;
GALE, DC ;
UDSETH, HR ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :586-593
[5]   A multiple channel electrospray source used to detect highly reactive ketenes from a flow pyrolyzer [J].
Hong, CM ;
Tsai, FC ;
Shiea, J .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1175-1178
[6]   ELECTROSPRAY ION SPRAY - A COMPARISON OF MECHANISMS AND PERFORMANCE [J].
IKONOMOU, MG ;
BLADES, AT ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :1989-1998
[7]   Nanoelectrospray -: More than just a minimized-flow electrospray ionization source [J].
Juraschek, R ;
Dülcks, T ;
Karas, M .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (04) :300-308
[8]   Determination of sedatives and anesthetics in plasma by liquid chromatography mass spectrometry with a desalting system [J].
Kanazawa, H ;
Konishi, Y ;
Matsushima, Y ;
Takahashi, T .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :227-236
[9]   Gas chromatography connected to multiple channel electrospray ionization mass spectrometry for the detection of volatile organic compounds [J].
Lee, CY ;
Shiea, J .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2757-2761
[10]   Quantitation of phosphorothioate oligonucleotides in human plasma [J].
Leeds, JM ;
Graham, MJ ;
Truong, L ;
Cummins, LL .
ANALYTICAL BIOCHEMISTRY, 1996, 235 (01) :36-43