Determination of sedatives and anesthetics in plasma by liquid chromatography mass spectrometry with a desalting system

被引:49
作者
Kanazawa, H
Konishi, Y
Matsushima, Y
Takahashi, T
机构
[1] Kyoritsu Coll Pharm, Tokyo 105, Japan
[2] Hitachi Instrument Engn Co Ltd, Katsuta, Ibaraki 312, Japan
关键词
enantiomer separation; desalting methods; sedatives; anaesthetics;
D O I
10.1016/S0021-9673(97)00928-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Though liquid chromatography-mass spectrometry (LC-MS) is a powerful tool for analysis of drugs and their metabolites, it does not allow the use of a non-volatile buffer such as phosphate buffer. We used a column-switching desalting system in combination with atmospheric pressure chemical ionization LC-MS for analysis of sedatives and anaesthetics. The drugs examined were flumazenil, butorphanol, midazolam, lorazepam, phenobarbital and flunitrazepam. The separation was carried out on a reversed-phase column using acetonitrile-0.1 M phosphate buffer as a mobile phase. The mass spectra are almost the same as those obtained by direct analysis and the molecular ions were clearly observed. In the analysis, phosphate buffer was completely removed with the trapping column and did not interfere with ionization of the drugs in MS. The chiral separation of lorazepam was achieved on a chiral column with UV, optical rotatory detection and MS. This method is sufficiently sensitive and accurate for the pharmacokinetic studies of these drugs in biological samples. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:227 / 236
页数:10
相关论文
共 13 条
[1]   SIMULTANEOUS DETERMINATION OF FLUMAZENIL, MIDAZOLAM AND METABOLITES IN HUMAN BIOLOGICAL-FLUIDS BY LIQUID-CHROMATOGRAPHY [J].
CHAN, K ;
JONES, RDM .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 619 (01) :154-160
[2]   STEREOCHEMISTRY OF ENZYMIC 3-HYDROXYLATION OF 1,3-DIHYDRO-2H-1,4-BENZODIAZEPIN-2-ONES [J].
CORBELLA, A ;
GARIBOLDI, P ;
JOMMI, G ;
FORGIONE, A ;
MARCUCCI, F ;
MARTELLI, P ;
MUSSINI, E ;
MAURI, F .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1973, (19) :721-722
[3]   THE DETERMINATION OF TOTAL AND UNBOUND MIDAZOLAM IN HUMAN PLASMA - A COMPARISON OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, GAS-CHROMATOGRAPHY AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
DEVRIES, JX ;
RUDI, J ;
WALTERSACK, I ;
CONRADI, R .
BIOMEDICAL CHROMATOGRAPHY, 1990, 4 (01) :28-33
[4]   PHARMACOKINETICS OF KETAMINE HCL AND METABOLITE-I IN THE CAT - A COMPARISON OF IV, IM, AND RECTAL ADMINISTRATION [J].
HANNA, RM ;
BORCHARD, RE ;
SCHMIDT, SL .
JOURNAL OF VETERINARY PHARMACOLOGY AND THERAPEUTICS, 1988, 11 (01) :84-93
[5]   DETERMINATION OF MEDETOMIDINE, ATIPAMEZOLE MIDAZOLAM IN PIG PLASMA BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
KANAZAWA, H ;
NISHIMURA, R ;
SASAKI, N ;
TAKEUCHI, A ;
TAKAI, N ;
NAGATA, Y ;
MATSUSHIMA, Y .
BIOMEDICAL CHROMATOGRAPHY, 1995, 9 (04) :188-191
[6]   LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY FOR THE DETERMINATION OF MEDETOMIDINE AND OTHER ANESTHETICS IN PLASMA [J].
KANAZAWA, H ;
NAGATA, Y ;
MATSUSHIMA, Y ;
TAKAI, N ;
UCHIYAMA, H ;
NISHIMURA, R ;
TAKEUCHI, A .
JOURNAL OF CHROMATOGRAPHY, 1993, 631 (1-2) :215-220
[7]   ENANTIOMER RESOLUTION OF CAMAZEPAM AND ITS DERIVATIVES AND ENANTIOSELECTIVE METABOLISM OF CAMAZEPAM BY HUMAN LIVER-MICROSOMES [J].
LU, XL ;
YANG, SK .
JOURNAL OF CHROMATOGRAPHY A, 1994, 666 (1-2) :249-257
[8]   RESOLUTION OF 4-(4-CHLOROBENZYL)-2-(HEXAHYDRO-1-METHYL-1H-AZEPIN-4YL)-1(2H)-PHTHALAZINONE ENANTIOMERS IN PLASMA WITH FRIT-FAB LC MS USING A CONALBUMIN COLUMN [J].
MANO, N ;
ODA, Y ;
OHE, H ;
ASAKAWA, N ;
YOSHIDA, Y ;
SATO, T .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (04) :557-567
[9]   HPLC DETERMINATION OF XYLAZINE IN EQUINE PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
MCDONNELL, T ;
KELLY, MT ;
SMYTH, MR .
ANALYTICAL LETTERS, 1993, 26 (07) :1547-1556
[10]   DETERMINATION OF KETAMINE AND SOME INVIVO METABOLITES USING HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
NEEDHAM, LL ;
KOCHHAR, MM .
JOURNAL OF CHROMATOGRAPHY, 1975, 114 (01) :220-222