Copper(II) ion sensor based on electropolymerized undoped conducting polymers

被引:23
作者
Prakash, R
Srivastava, RC
Pandey, PC
机构
[1] Ind Toxicol Res Ctr, Lucknow 226001, Uttar Pradesh, India
[2] Banaras Hindu Univ, Dept Chem, Varanasi 221005, Uttar Pradesh, India
关键词
conducting polymers; ion sensor; ion selective electrodes; electropolymerization;
D O I
10.1007/s100080100213
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A solid state copper(II) ion sensor is reported based on the application of electropolymerized undoped (neutral) polycarbazole (PCz) and polyindole (PIn) modified electrodes. The new sensor shows M selectivity to Cu2+ ions with a detection limit or 10(-5) M. PCz and PIn are formed respectively by the anodic oxidation of 50 mM carbazole and 5 mM indole monomers in dichloromethane containing 0.1 M tetrabutylammonium perchlorate on a platinum electrode using a single compartment cell. Potentiostatic polymerization of both the monomers are carried out at 1.3 V and 1.0 V vs. Ag/ AgCl, respectively. Perchlorate ions were electrochemically removed from the polymer films by applying - 0.2 V vs. Ag/AgCl. Polymer-coated electrodes are incubated in 1 M KCl solution for 8 h followed by incubation in distilled water for 2 h before using as a metal ion sensor. The undoped PCz and Phi electrodes were found to be highly selective and sensitive for Cu2+ ions with little selectivity for Pb2+ and negligible response towards Ag+, Hg2+, Cu+, Ni2+, Co2+, Fe2+, Fe3+ or Zn2+. Potentiometric responses for Cu2+ ions are recorded for both the sensor electrodes together with a double-junction A/AgCl reference electrode. Calibration curves for Cu2+ are reported for both ion sensors. The polymer-modified electrodes were found to be stable for several weeks.
引用
收藏
页码:203 / 208
页数:6
相关论文
共 10 条
[1]   SECONDARY DOPING IN POLYANILINE [J].
MACDIARMID, AG ;
EPSTEIN, AJ .
SYNTHETIC METALS, 1995, 69 (1-3) :85-92
[2]  
MOMMA T, 1995, SENSOR ACTUAT B-CHEM, V24, P724
[3]  
Pandey P. C., 1998, J ELECTROCHEM SOC, V145, P4301
[4]   A NEW CONDUCTING POLYMER-COATED GLUCOSE SENSOR [J].
PANDEY, PC .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1988, 84 :2259-2265
[5]  
Pandey PC, 2000, ELECTROANAL, V12, P517, DOI 10.1002/(SICI)1521-4109(200005)12:7<517::AID-ELAN517>3.3.CO
[6]  
2-P
[7]   Electrochemical synthesis of polyindole and its evaluation for rechargeable battery applications [J].
Pandey, PC ;
Prakash, R .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1998, 145 (03) :999-1003
[8]   Polyindole modified potassium ion sensor using dibenzo-18-crown-6 mediated PVC matrix membrane [J].
Pandey, PC ;
Prakash, R .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (01) :61-65
[9]   Copper(II) ion-selective microelectrochemical transistor [J].
Saxena, V ;
Shirodkar, V ;
Prakash, R .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2000, 4 (04) :234-236
[10]   POLYMER MEMBRANE-BASED ION-SELECTIVE, GAS-SELECTIVE AND BIO-SELECTIVE POTENTIOMETRIC SENSORS [J].
YIM, HS ;
KIBBEY, CE ;
MA, SC ;
KLIZA, DM ;
LIU, D ;
PARK, SB ;
TORRE, CE ;
MEYERHOFF, ME .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (01) :1-38