Detection of access strictures and outlet stenoses in vascular accesses - Which test is best?

被引:30
作者
Besarab, A [1 ]
Lubkowski, T [1 ]
Frinak, S [1 ]
Ramanathan, S [1 ]
Escobar, F [1 ]
机构
[1] HENRY FORD HOSP,DEPT SURG,DETROIT,MI 48202
关键词
D O I
10.1097/00002480-199709000-00039
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The location of stenoses within an access may influence the diagnostic value of access monitoring tests. Whereas decreasing access flow (Q(ACC)) should occur with both venous outlet stenoses and strictures within the body of the access, normalized intra-access venous pressure (vP(IA)/MAP) depends on location of the venous needle relative to the lesion. The authors determined the value of vP(IA)/MAP and direct measurement of percent access recirculation (AR) and Q(ACC) in detecting venous outlet stenoses and strictures. Abnormal access studies were evaluated by Doppler ultrasound and fistulography. Well functioning grafts and arteriovenous fistulas (AVFs) have no AR; Q(ACC) averages 1,101 +/- 26 and 1,073 +/- 35 ml/min, and vP(IA)/MAP ratios are 0.34 and 0.16, respectively. Venous outlet stenoses (n = 36) or strictures (n = 32) were detected before thrombosis or intervention in 172 vascular accesses at risk. Q(ACC) in accesses with stricture was significantly lower than in those with venous outlet stenosis (361 +/- 11 vs 526 +/- 43 ml/min), as was less than prescribed blood flow (423 +/- 7 ml/min). AR was not detected in any access with stricture and in only 4 of 36 accesses with outlet stenosis. vP(IA)/MAP was elevated with venous outlet stenosis but not with strictures. The findings of Q(ACC) being less than blood pump flow without AR by dilution methods differentiated strictures from venous outlet stenoses.
引用
收藏
页码:M543 / M547
页数:5
相关论文
共 19 条
  • [1] The relationship of recirculation to access blood flow
    Besarab, A
    Sherman, R
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 29 (02) : 223 - 229
  • [2] UTILITY OF INTRA-ACCESS PRESSURE MONITORING IN DETECTING AND CORRECTING VENOUS OUTLET STENOSES PRIOR TO THROMBOSIS
    BESARAB, A
    SULLIVAN, KL
    ROSS, RP
    MORITZ, MJ
    [J]. KIDNEY INTERNATIONAL, 1995, 47 (05) : 1364 - 1373
  • [3] Simplified measurement of intra-access pressure
    Besarab, A
    AlSaghir, F
    Alnabhan, N
    Lubkowski, T
    Frinak, S
    [J]. ASAIO JOURNAL, 1996, 42 (05) : M682 - M687
  • [4] BESARAB A, 1997, ASAIO J, V43, pM20
  • [5] Besarab A., 1995, J AM SOC NEPHROL, V7, P483
  • [6] DEPNER TA, 1995, ASAIO J, V41, pM745, DOI 10.1097/00002480-199507000-00112
  • [7] DEPNER TA, 1995, ASAIO J, V41, pM749, DOI 10.1097/00002480-199507000-00113
  • [8] Feldman HI, 1996, J AM SOC NEPHROL, V7, P523
  • [9] THEORY AND VALIDATION OF ACCESS FLOW MEASUREMENT BY DILUTION TECHNIQUE DURING HEMODIALYSIS
    KRIVITSKI, NM
    [J]. KIDNEY INTERNATIONAL, 1995, 48 (01) : 244 - 250
  • [10] VALUE OF CLINICAL SCREENING FOR DETECTION OF ASYMPTOMATIC HEMODIALYSIS VASCULAR ACCESS STENOSES
    LEVY, SS
    SHERMAN, RA
    NOSHER, JL
    [J]. ANGIOLOGY, 1992, 43 (05) : 421 - 424