Comparison of aspirin alone versus aspirin plus ticlopidine after coronary artery stenting

被引:50
作者
Goods, CM
AlShaibi, KF
Liu, MW
Yadav, JS
Mathur, A
Jain, SP
Dean, LS
Iyer, SS
Parks, JM
Roubin, GS
机构
[1] Cardiovascular Division, University of Alabama at Birmingham, Birmingham, AL
[2] Division of Cardiovascular Diseases, University of Alabama at Birmingham, Birmingham, AL 35294, 1808 7th Avenue South
关键词
D O I
10.1016/S0002-9149(96)00532-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This prospective nonrandomized study was performed comparing aspirin alone (n = 46) versus aspirin and ticlopidine (n = 338) following native coronary artery stenting. There were significantly more stent thrombosis events in the aspirin-only group than in the aspirin and ticlopidine group (6.5% vs 0.9%, p = 0.02) and significantly more Q-wave myocardial infarctions and cardiac-related deaths in the aspirin-only group than in the aspirin and ticlopidine group (6.5% vs 0% p = 0.002 and 4.4% vs 0.3%, p = 0.02, respectively).
引用
收藏
页码:1042 / 1044
页数:3
相关论文
共 10 条
  • [1] INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE
    COLOMBO, A
    HALL, P
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    MARTINI, G
    GAGLIONE, A
    GOLDBERG, SL
    TOBIS, JM
    [J]. CIRCULATION, 1995, 91 (06) : 1676 - 1688
  • [2] THE CANADIAN AMERICAN TICLOPIDINE STUDY (CATS) IN THROMBOEMBOLIC STROKE
    GENT, M
    EASTON, JD
    HACHINSKI, VC
    PANAK, E
    SICURELLA, J
    BLAKELY, JA
    ELLIS, DJ
    HARBISON, JW
    ROBERTS, RS
    TURPIE, AGG
    [J]. LANCET, 1989, 1 (8649) : 1215 - 1220
  • [3] GOODS CM, IN PRESS CIRCULATION
  • [4] A randomized comparison of combined ticlopidine and aspirin therapy versus aspirin therapy alone after successful intravascular ultrasound-guided stent implantation
    Hall, P
    Nakamura, S
    Maiello, L
    Itoh, A
    Blengino, S
    Martini, G
    Ferraro, M
    Colombo, A
    [J]. CIRCULATION, 1996, 93 (02) : 215 - 222
  • [5] A RANDOMIZED TRIAL COMPARING TICLOPIDINE HYDROCHLORIDE WITH ASPIRIN FOR THE PREVENTION OF STROKE IN HIGH-RISK PATIENTS
    HASS, WK
    EASTON, JD
    ADAMS, HP
    PRYSEPHILLIPS, W
    MOLONY, BA
    ANDERSON, S
    KAMM, B
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1989, 321 (08) : 501 - 507
  • [6] EMERGENT USE OF BALLOON-EXPANDABLE CORONARY-ARTERY STENTING FOR FAILED PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    HERRMANN, HC
    BUCHBINDER, M
    CLEMEN, MW
    FISCHMAN, D
    GOLDBERG, S
    LEON, MB
    SCHATZ, RA
    TIERSTEIN, P
    WALKER, CM
    HIRSHFELD, JW
    [J]. CIRCULATION, 1992, 86 (03) : 812 - 819
  • [7] SIZING THE GIANTURCO-ROUBIN CORONARY FLEXIBLE COIL STENT
    HO, DSW
    LIU, MW
    YER, S
    PARKS, JM
    ROUBIN, GS
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 32 (03): : 242 - 248
  • [8] MORICE MC, 1995, CIRCULATION S1, V92, P795
  • [9] THROMBOSIS OF A FLEXIBLE COIL CORONARY STENT - FREQUENCY, PREDICTORS AND CLINICAL OUTCOME
    NATH, FC
    MULLER, DWM
    ELLIS, SG
    ROSENSCHEIN, U
    CHAPEKIS, A
    QUAIN, L
    ZIMMERMAN, C
    TOPOL, EJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (03) : 622 - 627
  • [10] MAJOR CLINICAL EVENTS AFTER CORONARY STENTING - THE MULTICENTER REGISTRY OF ACUTE AND ELECTIVE GIANTURCO-ROUBIN STENT PLACEMENT
    SUTTON, JM
    ELLIS, SG
    ROUBIN, GS
    PINKERTON, CA
    KING, SB
    RAIZNER, AE
    HOLMES, DR
    KEREIAKES, DJ
    TOPOL, EJ
    [J]. CIRCULATION, 1994, 89 (03) : 1126 - 1137