摘要
Creatine bienzymatic potentiometric biosensors were prepared by immobilizing urease and creatinase with four different procedures on poly(vinylchloride) (PVC) ammonium membrane electrode containing palmitic acid prepared by using nonactine as an ammonium-ionophore. The analytical characteristics were investigated and were compared with those of the biosensor prepared by using carboxylated PVC. The effects of pH, buffer concentration, temperature, enzyme concentration and stirring rate, and enzyme immobilization procedures on the response to creatine of the biosensor were investigated. The linear working range and sensitivity of the biosensor were also determined. The creatine biosensor prepared by using the PVC membranes containing palmitic acid showed more effective performance than those of the carboxylated PVC based biosensors. Additionally, creatine assay in serum was successfully carried out by using the standard addition method without any pretreatment. The results were good agreement with those obtained from Jaffe methods at 95% confidence level. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1371 / 1377
页数:7
相关论文
共 37 条
[1]   Polypyrrole-based amperometric flow injection biosensor for urea [J].
Adeloju, SB ;
Shaw, SJ ;
Wallace, GG .
ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) :107-113
[2]   CHARACTERISTICS OF UNBUFFERED GEL-IMMOBILIZED UREASE PARTICLES .2. OVERALL RATE OF REACTION [J].
ATKINSON, B ;
ROUSSEAU, I .
BIOTECHNOLOGY AND BIOENGINEERING, 1977, 19 (07) :1065-1086
[3]  
BICKERSTAFF GF, 1997, METHODS BIOTECHNOLOG, P261
[4]   ION SELECTIVE ELECTRODES, POTENTIOMETRY, AND POTENTIOMETRIC TITRATIONS [J].
BUCK, RP .
ANALYTICAL CHEMISTRY, 1972, 44 (05) :R270-+
[5]   ENZYME UREA BIOSENSOR BASED ON A MODIFIED POTENTIOMETRIC PVC-NONACTIN MEMBRANE-ELECTRODE FOR ASSAY OF UREA IN BLOOD [J].
BUTT, SB ;
CAMMANN, K .
ANALYTICAL LETTERS, 1992, 25 (09) :1597-1615
[6]   A disposable biosensor for urea determination in blood based on an ammonium-sensitive transducer [J].
Eggenstein, C ;
Borchardt, M ;
Diekmann, C ;
Gründig, B ;
Dumschat, C ;
Cammann, K ;
Knoll, M ;
Spener, F .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (01) :33-41
[7]  
EVANS A, 1991, POTENTIOMETRY IONSEL
[8]  
FISHBEIN WN, 1965, J BIOL CHEM, V240, P2402
[9]   AUTOMATED-DETERMINATION OF AMMONIA WITH A POTENTIOMETRIC GAS SENSOR AND FLOWING INTERNAL ELECTROLYTE [J].
FRATICELLI, YM ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1981, 53 (07) :992-997
[10]   ENZYME ELECTRODE AND THERMISTOR PROBES FOR DETERMINATION OF ALCOHOLS WITH ALCOHOL OXIDASE [J].
GUILBAULT, GG ;
DANIELSSON, B ;
MANDENIUS, CF ;
MOSBACH, K .
ANALYTICAL CHEMISTRY, 1983, 55 (09) :1582-1585