A disposable biosensor for urea determination in blood based on an ammonium-sensitive transducer

被引:86
作者
Eggenstein, C
Borchardt, M
Diekmann, C
Gründig, B
Dumschat, C
Cammann, K
Knoll, M
Spener, F
机构
[1] Inst Chemo & Biosensorik Munster, D-48149 Munster, Germany
[2] Univ Munster, Inst Biochem, D-48149 Munster, Germany
关键词
disposable biosensor; disposable reference electrode; potentiometric biosensor; urea biosensor; blood urea;
D O I
10.1016/S0956-5663(98)00103-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A potentiometric urea-sensitive biosensor using a NH4+-sensitive disposable electrode in double matrix membrane (DMM) technology as transducer is described. The ion-sensitive polymer matrix membrane was formed in the presence of an additional electrochemical inert filter paper matrix to improve the reproducibility in sensor production. The electrodes were prepared from one-side silver-coating filter paper, which is encapsulated for insulation by a heat-sealing film. Adefined volume of the NH4+-sensitive polymer matrix membrane cocktail was deposited on this filter paper. To obtain the urea-biosensor a layer of urease was cast onto the ion-sensitive membrane. Poly (carbamoylsulfonate) hydrogel, produced from a hydrophilic polyurethane prepolymer blocked with bisulfite, served as immobilisation material. The disposable urea-sensitive electrode was combined with a disposable Ag/AgCl reference electrode to obtain the disposable urea biosensor. The sensor responded rapidly and in a stable manner to changes in urea concentrations between 7.2 x 10(-5) and 2.1 x 10(-2) mol/l. The detection limit was 2 x 10-5 mol/l urea and the slope in the linear range 52 mV/decade. By taking into consideration the influence of the interfering K+- and Na+- ions the sensor can be used for the determination of urea in human blood and serum samples (diluted or undiluted). A good correlation was found with the data obtained by the spectrophotometric routine method. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 28 条
  • [1] BATTAGLIA CJ, 1980, Patent No. 4214968
  • [2] BERNT E, 1970, METHODEN ENZYMATISCH, V1, P1738
  • [3] DISPOSABLE SODIUM ELECTRODES
    BORCHARDT, M
    DIEKMANN, C
    DUMSCHAT, C
    CAMMANN, K
    KNOLL, M
    [J]. TALANTA, 1994, 41 (06) : 1025 - 1028
  • [4] BORCHARDT M, 1995, SENSOR ACTUAT B-CHEM, V24, P721
  • [5] NEW ENZYME SENSORS FOR UREA AND CREATININE ANALYSIS
    CAMPANELLA, L
    MAZZEI, F
    SAMMARTINO, MP
    TOMASSETTI, M
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1990, 23 (02): : 195 - 202
  • [6] DISPOSABLE REFERENCE ELECTRODE
    DIEKMANN, C
    DUMSCHAT, C
    CAMMANN, K
    KNOLL, M
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) : 276 - 278
  • [7] DOUBLE MATRIX MEMBRANES FOR POTENTIOMETRIC CATION-SELECTIVE DISPOSABLE SENSORS
    DUMSCHAT, C
    BORCHARDT, M
    DIEKMANN, C
    HEPKE, J
    CAMMANN, K
    KNOLL, M
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (8-9): : 553 - 555
  • [8] RESPONSE OF AN ENZYME-MODIFIED PH-SENSITIVE ION-SELECTIVE DEVICE - ANALYTICAL SOLUTION FOR THE RESPONSE IN THE PRESENCE OF PH BUFFER
    EDDOWES, MJ
    [J]. SENSORS AND ACTUATORS, 1987, 11 (03): : 265 - 274
  • [9] POTENTIOMETRIC BIOSENSOR IN DOUBLE MATRIX MEMBRANE TECHNOLOGY
    EGGENSTEIN, C
    BORCHARDT, M
    DUMSCHAT, C
    GRUNDIG, B
    CAMMANN, K
    SPENER, F
    KNOLL, M
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7) : 595 - 600
  • [10] A RAPID AND PRECISE METHOD FOR THE DETERMINATION OF UREA
    FAWCETT, JK
    SCOTT, JE
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1960, 13 (02) : 156 - 159