Image-guided spinal surgery

被引:54
作者
Holly, Langston T. [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Neurosurg, Los Angeles, CA 90095 USA
关键词
spinal; image; guidance; computer;
D O I
10.1002/rcs.69
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The purpose of this review is to present a comprehensive summary of commonly used methods of spinal image guidance, including the benefits and limitations of this novel technology. Methods The relevant medical literature was examined, supplemented by the author's laboratory and clinical experience with image-guided spinal surgery. Results Spinal image guidance has undergone significant evolution and rapid technological advancement in recent years. Image guidance provides three-dimensional visualization of the spine that can be used for preoperative planning and intraoperative navigation. There are three commonly used methods of spinal image guidance: preoperative CTbased, fluoroscopy-based, and 3D fluoroscopy. Each of these methods demonstrates lower rates of spinal implant misplacement than non-imageguided techniques. Conclusions Image guidance provides highly accurate intraoperative navigation and the medical literature suggests that this technology increases the safety of a variety of routine and complex spinal procedures. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:7 / 15
页数:9
相关论文
共 23 条
[1]   Bone registration method for robot assisted surgery: Pedicle screw insertion [J].
AbdelMalek, K ;
McGowan, DP ;
Goel, VK ;
Kowalski, D ;
Smith, SB .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (03) :221-233
[2]   Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine [J].
Amiot, LP ;
Lang, K ;
Putzier, M ;
Zippel, H ;
Labelle, H .
SPINE, 2000, 25 (05) :606-614
[3]   Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement [J].
Bloch, O ;
Holly, LT ;
Park, J ;
Obasi, C ;
Kim, K ;
Johnson, JP .
JOURNAL OF NEUROSURGERY, 2001, 95 (01) :74-79
[4]  
Bodner J, 2005, AM SURGEON, V71, P281
[5]   EXTRACRANIAL APPLICATION OF THE FRAMELESS STEREOTAXIC OPERATING MICROSCOPE - EXPERIENCE WITH LUMBAR SPINE [J].
BRODWATER, BK ;
ROBERTS, DW ;
NAKAJIMA, T ;
FRIETS, EM ;
STROHBEHN, JW ;
KELLY, PJ ;
FRIEDMAN, WA .
NEUROSURGERY, 1993, 32 (02) :209-213
[6]   Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[7]   Current status of endoscopic and robotic mitral valve surgery [J].
Chitwood, WR .
ANNALS OF THORACIC SURGERY, 2005, 79 (06) :S2248-S2253
[8]   Computer-assisted fluoroscopic targeting system for pedicle screw insertion [J].
Choi, WW ;
Green, BA ;
Levi, ADO .
NEUROSURGERY, 2000, 47 (04) :872-878
[9]   Virtual fluoroscopy: Computer-assisted fluoroscopic navigation [J].
Foley, KT ;
Simon, DA ;
Rampersaud, YR .
SPINE, 2001, 26 (04) :347-351
[10]  
Foley KT, 1996, NEUROSURG CLIN N AM, V7, P171