Diffusion-weighted imaging of the liver:: Optimizing b value for the detection and characterization of benign and malignant hepatic lesions

被引:88
作者
Goshima, Satoshi [1 ]
Kanematsu, Masayuki [1 ,2 ]
Kondo, Hiroshi [1 ]
Yokoyama, Ryujiro [2 ]
Kajita, Kimihiro [2 ]
Tsuge, Yusuke [1 ]
Watanabe, Haruo [1 ]
Shiratori, Yoshimune [3 ]
Onozuka, Minoru [4 ]
Moriyama, Noriyuki [5 ]
机构
[1] Gifu Univ, Sch Med, Dept Radiol, Gifu 500, Japan
[2] Gifu Univ, Sch Med, Dept Radiol Serv, Gifu 500, Japan
[3] Gifu Univ, Sch Med, Dept Med Informat, Gifu 500, Japan
[4] Kanagawa Dent Coll, Dept Physiol & Neurosci, Yokosuka, Kanagawa 238, Japan
[5] Natl Canc Ctr Hosp, Res Ctr Canc Prevent & Screening, Tsukiji, Japan
关键词
liver; MRI; diffusion;
D O I
10.1002/jmri.21467
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the optimal b values required for diffusion-weighted (DW) imaging of the liver in the detection and characterization of benign and malignant hepatic lesions. Materials and Methods: MR images obtained in 76 patients including 28 malignant hepatic lesions (21 hepatocellular carcinomas and 7 metastases) and 27 benign lesions (12 hemangiomas and 15 cysts) were reviewed. DW-echo planner images (EPIs: b values with 100, 200, 400, and 800 s/mm(2)) were reviewed solely first, and then with T2-weighted EPIs (b = 0 s/mm(2)). Results: Sensitivity for malignant lesions (74%) was highest on DW-EPIs with b value of 100 s/mm(2) and T2-weighted EPIs combined (P < 0.05), and sensitivity for benign lesions (87%) was highest on DW-EPIs with b value of 800 s/mm(2) and T2-weighted EPIs (P < 0.05). Specificities were comparably high for all sequences. The Az values for malignant lesions were 0.94, 0.90, 0.87, and 0.89, and those for benign lesions were 0.91, 0.89, 0.87, and 0.94 on DW-EPIs with b values of 100, 200, 400, and 800 and T2-weighted EPIs combined. respectively. Hepatic cysts were clearly distinguished with the cutoff ADC value of 2.5 x 10(-3) mm(2)/s using a b value of 400 s/mm2 or greater. Conclusion: DW-EPIs with middle b values were not required in the detection and characterization of benign and malignant hepatic lesions.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 15 条
[1]   Improved focal liver lesion detection:: comparison of single-shot diffusion-weighted echoplanar and single-shot T2 weighted turbo spin echo techniques [J].
Coenegrachts, K. ;
Delanote, J. ;
Ter Beek, L. ;
Haspeslagh, M. ;
Bipat, S. ;
Stoker, J. ;
Van Kerkhove, F. ;
Steyaert, L. ;
Rigauts, H. ;
Casselman, J. W. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (955) :524-531
[2]  
FLEISS JL, 1986, ANAL VARIANCE MULTIP, P51
[3]   Diffusion-tensor MR imaging at 1.5 and 3.0 T: Initial observations [J].
Hunsche, S ;
Moseley, ME ;
Stoeter, P ;
Hedehus, M .
RADIOLOGY, 2001, 221 (02) :550-556
[4]   Diffusion-weighted MR imaging with a single-shot echoplanar sequence: Detection and characterization of focal hepatic lesions [J].
Ichikawa, T ;
Haradome, H ;
Hachiya, J ;
Nitatori, T ;
Araki, T .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :397-402
[5]   Atypically enhancing hepatic cavernous hemangiomas: high-spatial-resolution gadolinium-enhanced triphasic dynamic gradient-recalled-echo imaging findings [J].
Kato, H ;
Kanematsu, M ;
Matsuo, M ;
Kondo, H ;
Hoshi, H .
EUROPEAN RADIOLOGY, 2001, 11 (12) :2510-2515
[6]   Diffusion-weighted single-shot echoplanar MR imaging for liver disease [J].
Kim, T ;
Murakami, T ;
Takahashi, S ;
Hori, M ;
Tsuda, K ;
Nakamura, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (02) :393-398
[7]   SEPARATION OF DIFFUSION AND PERFUSION IN INTRAVOXEL INCOHERENT MOTION MR IMAGING [J].
LEBIHAN, D ;
BRETON, E ;
LALLEMAND, D ;
AUBIN, ML ;
VIGNAUD, J ;
LAVALJEANTET, M .
RADIOLOGY, 1988, 168 (02) :497-505
[8]   Diffusion-weighted MRI (DWI) in the oncology patient: Value of breathhold DWI compared to unenhanced and gadolinium-enhanced MRI [J].
Low, Russell N. ;
Gurney, Jonathan .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (04) :848-858
[9]   Detection of malignant hepatic tumors: Comparison of gadolinium- and ferumoxide-enhanced MR imaging [J].
Matsuo, M ;
Kanematsu, M ;
Itoh, K ;
Ito, K ;
Maetani, Y ;
Kondo, H ;
Kako, N ;
Matsunaga, N ;
Hoshi, H ;
Shiraishi, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (03) :637-643
[10]  
MULLER MF, 1994, RADIOLOGY, V190, P475