Improved focal liver lesion detection:: comparison of single-shot diffusion-weighted echoplanar and single-shot T2 weighted turbo spin echo techniques

被引:123
作者
Coenegrachts, K.
Delanote, J.
Ter Beek, L.
Haspeslagh, M.
Bipat, S.
Stoker, J.
Van Kerkhove, F.
Steyaert, L.
Rigauts, H.
Casselman, J. W.
机构
[1] AZ St Jan AV, Dept Radiol, B-8000 Brugge, Belgium
[2] Philips Med Syst, Best, Netherlands
[3] AZ St Jan AV, Dept Radiol, Hosp Adm & Stat, B-8000 Brugge, Belgium
[4] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
关键词
D O I
10.1259/bjr/33156643
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare diffusion-weighted respiratory-triggered single-shot spin echo echoplanar imaging (SS SE-EPI) sequence using four b-values (b=0, b=20, b=300, b=800 s mm(-2)) and single-shot T-2 weighted turbo spin echo (T2W SS TSE) in patients with focal liver lesions, with special interest in small (<10 mm) lesions. Twenty-four patients underwent routine MRI The five sequences were compared qualitatively for image quality, lesion conspicuity and artefacts. Quantitative analysis was performed for lesion identification and lesion-to-liver contrast-to-noise ratio (CNR). Subgroup analyses were performed for different types of lesions with different sizes. Sequences were compared by rank order statistic (RIDIT) and Kruskal-Wallis test. The best image quality (p<0.05) was achieved with T2W TSE and the best lesion conspicuity (p<0.05) with T2W TSE for biliary cysts and SE-EPI diffusion-weighted imaging (DWI) (b=20 s mm(-2)) for haemangiomas and metastases. Image artefacts were lowest (p<0.05) with T2W TSE. T2W TSE was found to be the best protocol (p<0.05) for the identification of biliary cysts and SE-EPI DWI (b=20 s mm(-2) for haemangiomas and metastases. The lesion-to-liver CNRs were highest on T2W TSE for biliary cysts and on SE-EPI diffusion-weighted imaging (DWI) for haemangiomas and metastases (p<0.05). This study shows the potential of SS SE-EIPI DWI (especially with a b-value of 20 s mm(-2)) as a promising technique for detecting small (<10 mm) focal liver lesions. (C) 2007 The British Institute of Radiology.
引用
收藏
页码:524 / 531
页数:8
相关论文
共 22 条
  • [1] HOW TO USE RIDIT ANALYSIS
    BROSS, IDJ
    [J]. BIOMETRICS, 1958, 14 (01) : 18 - 38
  • [2] ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    FELMLEE, JP
    GRIMM, RC
    [J]. RADIOLOGY, 1993, 189 (01) : 259 - 264
  • [3] ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING
    FARZANEH, F
    RIEDERER, SJ
    PELC, NJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) : 123 - 139
  • [4] Fleiss J. L., 1981, Statistical Methods for Rates and Proportions, V2nd
  • [5] VALUE OF T1-RELAXATION AND T2-RELAXATION TIMES FROM ECHOPLANAR MR IMAGING IN THE CHARACTERIZATION OF FOCAL HEPATIC-LESIONS
    GOLDBERG, MA
    HAHN, PF
    SAINI, S
    COHEN, MS
    REIMER, P
    BRADY, TJ
    MUELLER, PR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) : 1011 - 1017
  • [6] Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging
    Hori, M
    Murakami, T
    Kim, T
    Kanematsu, M
    Tsuda, K
    Takahashi, S
    Takamura, M
    Hoshi, H
    Nakamura, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) : 1423 - 1431
  • [7] T2-weighted MR imaging in the assessment of cirrhotic liver
    Hussain, HK
    Syed, I
    Nghiem, HV
    Johnson, TD
    Carlos, RC
    Weadock, WJ
    Francis, IR
    [J]. RADIOLOGY, 2004, 230 (03) : 637 - 644
  • [8] Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study
    Hussain, SM
    De Becker, J
    Hop, WCJ
    Dwarkasing, S
    Wielopolski, PA
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) : 219 - 229
  • [9] Diffusion-weighted MR imaging with a single-shot echoplanar sequence: Detection and characterization of focal hepatic lesions
    Ichikawa, T
    Haradome, H
    Hachiya, J
    Nitatori, T
    Araki, T
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 397 - 402
  • [10] JANSEN ME, 1984, RIDIT ANAL REV STAT, V38, P141