Investigation of the chromate conversion coating on Alclad 2024 aluminium alloy: effect of the pH of the chromate bath

被引:47
作者
Campestrini, P
van Westing, EPM
Hovestad, A
de Wit, JHW
机构
[1] Netherlands Inst Met Res, NL-2600 GA Delft, Netherlands
[2] Delft Univ Technol, Dept Mat Sci, Sect Corros Technol & Electrochem, Fac Sci Appl, NL-2628 AL Delft, Netherlands
[3] TNO, Ind Technol Inst, NL-5600 HE Eindhoven, Netherlands
关键词
impedance; chromate; conversion coating; corrosion protection;
D O I
10.1016/S0013-4686(01)00818-0
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The parameters of the chromate bath, like temperature, pH, and fluoride content. strongly affect the morphology and chemical composition of the chromate conversion coating and as a consequence have a large influence on its corrosion performance. In this paper, electrochemical impedance spectroscopy (EIS) was used in combination with other techniques to investigate the role played by the pH of the chromate bath on the properties of the chromate film formed on Alclad 2024 aluminium alloy. Scanning electron microscopy (SEM), atomic force microscopy (AFM) and spectroscopic ellipsometry (SE) have shown the formation of a thicker and less dense chromate layer when the pH of the chromate bath is changed from 2.4 to 1.2. The analysis of the EIS spectra have highlighted that this change in pH leads to the formation of more protective and more resistant chromate corrosion products (CCP) inside the defects of the chromate film. When a thin, dense and protective layer of CCP is formed in the defects, the corrosion behaviour of the chromate conversion coating improves for two main reason: (a) further attack of the defects is avoided or delayed; (b) the change in volume caused by the formation of the CCP is limited resulting in a low level of stress in the film, which as a consequence is not detached from the aluminium substrate. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1097 / 1113
页数:17
相关论文
共 27 条