MASS SPECTROMETRY FOR STRUCTURAL CHARACTERIZATION OF THERAPEUTIC ANTIBODIES

被引:244
作者
Zhang, Zhongqi [1 ]
Pan, Hai [1 ]
Chen, Xiaoyu [1 ]
机构
[1] Amgen Inc, Proc & Product Dev, Thousand Oaks, CA 91320 USA
关键词
immunoglobulin; monoclonal antibody; disulfide; glycan; middle-up; bottom-tip; top-down; middle-down; TIME-OF-FLIGHT; RECOMBINANT MONOCLONAL-ANTIBODY; ASSISTED-LASER-DESORPTION/IONIZATION; N-LINKED GLYCANS; LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY; COLLISION-INDUCED DISSOCIATION; ELECTRON-CAPTURE DISSOCIATION; IMMUNOGLOBULIN-GAMMA-ANTIBODIES; PROTEIN GLYCOSYLATION ANALYSIS; ANION-EXCHANGE CHROMATOGRAPHY;
D O I
10.1002/mas.20190
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Antibodies, also known as immunoglobulins, have emerged as one of the most promising classes of therapeutics in the biopharmaceutical industry The need for complete characterization of the quality attributes of these molecules requires sophisticated techniques. Mass spectrometry (MS) has become an essential analytical tool for the structural characterization of therapeutic antibodies, due to its superior resolution over other analytical techniques. It has been widely used in virtually all phases of antibody development. Structural features determined by MS include amino acid sequence, disulfide linkages, carbohydrate structure and profile, and many different post-translational, in-process, and in-storage modifications. In this review, we will discuss various MS-based techniques for the structural characterization of monoclonal antibodies. These techniques are categorized as mass determination of intact antibodies, and as middle-tip, bottom-up, top-down, and middle-down structural characterizations. Each of these techniques has its advantages and disadvantages in terms of structural resolution, sequence coverage, sample consumption, and effort required for analyses. The role of MS in glycan structural characterization and profiling will also be discussed. (C) 2008 Wiley Periodicals, Inc., Mass Spec Rev 28:147-176, 2009
引用
收藏
页码:147 / 176
页数:30
相关论文
共 238 条
[91]   EXAMINATION OF COMPLEX OLIGOSACCHARIDES BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY ON TIME-OF-FLIGHT AND MAGNETIC-SECTOR INSTRUMENTS [J].
HARVEY, DJ ;
RUDD, PM ;
BATEMAN, RH ;
BORDOLI, RS ;
HOWES, K ;
HOYES, JB ;
VICKERS, RG .
ORGANIC MASS SPECTROMETRY, 1994, 29 (12) :753-766
[92]   Structural determination of N-linked glycans by matrix-assisted laser desorption/ionization and electrospray ionization mass spectrometry [J].
Harvey, DJ .
PROTEOMICS, 2005, 5 (07) :1774-1786
[93]   Mass spectrometric analysis of N- and O-glycosylation of tissues and cells [J].
Haslam, Stuart M. ;
North, Simon J. ;
Dell, Anne .
CURRENT OPINION IN STRUCTURAL BIOLOGY, 2006, 16 (05) :584-591
[94]   IDENTIFYING PROTEINS FROM 2-DIMENSIONAL GELS BY MOLECULAR MASS SEARCHING OF PEPTIDE-FRAGMENTS IN PROTEIN-SEQUENCE DATABASES [J].
HENZEL, WJ ;
BILLECI, TM ;
STULTS, JT ;
WONG, SC ;
GRIMLEY, C ;
WATANABE, C .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (11) :5011-5015
[95]   Automated protein identification by tandem mass spectrometry:: Issues and strategies [J].
Hernandez, P ;
Müller, M ;
Appel, RD .
MASS SPECTROMETRY REVIEWS, 2006, 25 (02) :235-254
[96]   Metabolic control of recombinant monoclonal antibody N-glycosylation in GS-NS0 cells [J].
Hills, AE ;
Patel, A ;
Boyd, P ;
James, DC .
BIOTECHNOLOGY AND BIOENGINEERING, 2001, 75 (02) :239-251
[97]   Complete and rapid peptide and glycopeptide mapping of mouse monoclonal antibody by LC/MS/MS using ion trap mass spectrometry [J].
Hirayama, K ;
Yuji, R ;
Yamada, N ;
Kato, K ;
Arata, Y ;
Shimada, I .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2718-2725
[98]   Complementary structural information from a tryptic N-linked glycopeptide via electron transfer ion/ion reactions and collision-induced dissociation [J].
Hogan, JM ;
Pitteri, SJ ;
Chrisman, PA ;
McLuckey, SA .
JOURNAL OF PROTEOME RESEARCH, 2005, 4 (02) :628-632
[99]   Protein analysis by hydrogen exchange mass spectrometry [J].
Hoofnagle, AN ;
Resing, KA ;
Ahn, NG .
ANNUAL REVIEW OF BIOPHYSICS AND BIOMOLECULAR STRUCTURE, 2003, 32 :1-25
[100]   The Orbitrap: a new mass spectrometer [J].
Hu, QZ ;
Noll, RJ ;
Li, HY ;
Makarov, A ;
Hardman, M ;
Cooks, RG .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (04) :430-443