Simultaneous measurement of refractive index and thickness of transparent plates by low coherence interferometry

被引:52
作者
Ohmi, M [1 ]
Shiraishi, T [1 ]
Tajiri, H [1 ]
Haruna, M [1 ]
机构
[1] OSAKA UNIV, GRAD SCH ENGN, COURSE ELECT ENGN, SUITA, OSAKA 565, JAPAN
关键词
low coherence light source; interferometry; simultaneous measurement of index and thickness; opto-electronics; precise mechanics;
D O I
10.1007/s10043-997-0507-1
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate a novel low coherence Michelson interferometer which can provide simultaneous measurement of the refractive index and thickness of transparent plates used as a measured object. Unlike the existing low coherence interferometers reported so fat, either an object or a focusing lens aligned on the signal arm is scanned repeatedly by a precise translation stage in synchronization with movement of a reflection mirror on the reference arm. The so-called object or lens scanning method gives us two measured quantities a movement distance of the stage between two light focusing states on the front and rear planes of an object and the corresponding optical path difference. These two measured quantities, result in desirable values of the index and thickness of the object with a short calculation. The measurement accuracy of less than or equal to 0.1% is expected for a thickness of more than 1 mm. In the experiment using the object scanning method, the accuracy of 0.3% or less was successfully attained for nearly l-mm thick plates of fused quartz, sapphire, LiTaO3 and slide glass.
引用
收藏
页码:507 / 515
页数:9
相关论文
共 15 条
[1]   DEPTH RESPONSE OF CONFOCAL OPTICAL MICROSCOPES [J].
CORLE, TR ;
CHOU, CH ;
KINO, GS .
OPTICS LETTERS, 1986, 11 (12) :770-772
[2]   MEASUREMENT OF THE THICKNESS OF FUNDUS LAYERS BY PARTIAL COHERENCE TOMOGRAPHY [J].
DREXLER, W ;
HITZENBERGER, CK ;
SATTMANN, H ;
FERCHER, AF .
OPTICAL ENGINEERING, 1995, 34 (03) :701-710
[3]   EYE-LENGTH MEASUREMENT BY INTERFEROMETRY WITH PARTIALLY COHERENT-LIGHT [J].
FERCHER, AF ;
MENGEDOHT, K ;
WERNER, W .
OPTICS LETTERS, 1988, 13 (03) :186-188
[4]   Simultaneous measurement of thicknesses and refractive indices of multiple layers by a low-coherence confocal interference microscope [J].
Fukano, T ;
Yamaguchi, I .
OPTICS LETTERS, 1996, 21 (23) :1942-1944
[5]   SUBMILLIMETER OPTICAL REFLECTOMETRY [J].
GILGEN, HH ;
NOVAK, RP ;
SALATHE, RP ;
HODEL, W ;
BEAUD, P .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1989, 7 (08) :1225-1233
[6]   MEASUREMENT OF CORNEAL THICKNESS BY LOW-COHERENCE INTERFEROMETRY [J].
HITZENBERGER, CK .
APPLIED OPTICS, 1992, 31 (31) :6637-6642
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]  
KUDO K, 1972, FIGURES TABLES BASIC, P266
[9]  
OHMI M, 1996, P 11 INT C OPT FIB S, P332
[10]   HIGH-SPEED OPTICAL COHERENCE DOMAIN REFLECTOMETRY [J].
SWANSON, EA ;
HUANG, D ;
HEE, MR ;
FUJIMOTO, JG ;
LIN, CP ;
PULIAFITO, CA .
OPTICS LETTERS, 1992, 17 (02) :151-153