PET imaging using dual-headed gamma cameras: An update

被引:42
作者
Lewellen, TK [1 ]
Miyaoka, RS [1 ]
Swan, WL [1 ]
机构
[1] Univ Washington, Sch Med, Div Nucl Med, Seattle, WA 98105 USA
关键词
D O I
10.1097/00006231-199901000-00003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Interest in clinical fluorodeoxyglucose (FDG) imaging with dual-headed gamma cameras continues to grow. In 1996, Jarritt and Acton published a review article of the use of gamma-camera systems for FDG imaging [1]. Since that article was published, considerable progress has been made in the adaptation of dual-headed camera systems for coincidence imaging. We review the basic principles of dual-headed coincidence imaging and some of the major limitations and challenges in the development of such technology. Since much of the current clinical experience with FDG imaging is based on the use of dedicated position emission tomographic (PET) systems, some comparisons of the performance Limitations between dual-headed gamma-camera and dedicated PET systems are provided. ((C) 1999 Lippincott Williams & Wilkins).
引用
收藏
页码:5 / 12
页数:8
相关论文
共 35 条
[1]  
ANGER HO, 1967, INSTRUMENTATION NUCL
[2]   List-mode likelihood [J].
Barrett, HH ;
White, T ;
Parra, LC .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) :2914-2923
[3]   INCREASED SENSITIVITY AND FIELD OF VIEW FOR A ROTATING POSITRON CAMERA [J].
CLACK, R ;
TOWNSEND, D ;
JEAVONS, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (11) :1421-1431
[4]  
DAUBEWITHERSPOON ME, 1987, J NUCL MED, V28, P1717
[5]   POST-INJECTION TRANSMISSION ATTENUATION MEASUREMENTS FOR PET [J].
DAUBEWITHERSPOON, ME ;
CARSON, RE ;
GREEN, MV .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :757-761
[6]   IMPLEMENTATION OF 3-DIMENSIONAL IMAGE-RECONSTRUCTION FOR MULTIRING POSITRON TOMOGRAPHS [J].
DEFRISE, M ;
TOWNSEND, D ;
GEISSBUHLER, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1361-1372
[7]   Exact and approximate rebinning algorithms for 3-D PET data [J].
Defrise, M ;
Kinahan, PE ;
Townsend, DW ;
Michel, C ;
Sibomana, M ;
Newport, DF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :145-158
[8]  
Defrise M., 1995, Proceedings of the 1995 International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, P235
[9]   A NEW 3-DIMENSIONAL RECONSTRUCTION METHOD FOR POSITRON CAMERAS USING PLANE DETECTORS [J].
DEFRISE, M ;
KUIJK, S ;
DECONINCK, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01) :43-51
[10]   ATTENUATION CORRECTION IN PET USING SINGLE-PHOTON TRANSMISSION MEASUREMENT [J].
DEKEMP, RA ;
NAHMIAS, C .
MEDICAL PHYSICS, 1994, 21 (06) :771-778