Demonstration of isoelectric focusing on an etched quartz chip with UV absorption imaging detection

被引:79
作者
Mao, QL [1 ]
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1039/a809756i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of isoelectric focusing (IEF) performed on-chip was demonstrated for the first time via absorption imaging detection. Microchannels on a quartz chip were fabricated using photolithography and a chemical etching process. The separation channels were 40 mm long, 100 mu m wide and 10 mu m deep, and were coated with linear polyacrylamide to reduce electroosmotic flow. A quartz chip cartridge for IEF was assembled in which two pieces of hollow fiber were glued to the two ends of the separation channel to isolate the electrolytes from the samples. Low molecular mass pi markers and myoglobin were selected as model samples which were mixed with 4% carrier ampholyte solution. Samples were injected into the channel via the connection capillary by pressure. A voltage of 3 kV was applied to perform IEF. The IEF current decreased from about 13.4 to 1.3 mu A. The focused zones were monitored in real time by absorption imaging detection at 280 mn. The detection limit was about 0.3 mu g ml(-1) or 24 pg for pl marker 6.6, and 30 mu g ml(-1) or 2.4 ng for myoglobin with an optical pathlength of 10 mu m. Good reproducibility and resolution were obtained for linear polyacrylamide coated channels. The total analysis time was less than 10 min. This imaged chip IEF provides a fast separation technique with quantitative ability and the potential for increasing throughput.
引用
收藏
页码:637 / 641
页数:5
相关论文
共 29 条
[1]   Lowering the UV absorbance detection limit in capillary zone electrophoresis using a single linear photodiode array detector [J].
Culbertson, CT ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2629-2638
[2]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[3]   MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :177-184
[4]   Solid state array detectors for analytical spectrometry [J].
Harnly, JM ;
Fields, RE .
APPLIED SPECTROSCOPY, 1997, 51 (09) :A334-A351
[5]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[6]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[7]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[8]   OPEN-CHANNEL ELECTROCHROMATOGRAPHY ON A MICROCHIP [J].
JACOBSON, SC ;
HERGENRODER, R ;
KOUTNY, LB ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2369-2373
[9]   PRECOLUMN REACTIONS WITH ELECTROPHORETIC ANALYSIS INTEGRATED ON A MICROCHIP [J].
JACOBSON, SC ;
HERGENRODER, R ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4127-4132
[10]   Microfabrication of a planar absorbance and fluorescence cell for integrated capillary electrophoresis devices [J].
Liang, ZH ;
Chiem, N ;
Ocvirk, G ;
Tang, T ;
Fluri, K ;
Harrison, DJ .