Safe and effective method of stabilization for coronary artery bypass grafting on the beating heart

被引:60
作者
Shennib, H
Lee, AGL
Akin, J
机构
[1] Department of Cardiothoracic Surgery, McGill University, Montreal, Que.
[2] Montreal General Hospital, Montreal, Que. H3G 1A4
关键词
D O I
10.1016/S0003-4975(97)00010-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. There is an emerging interest in performing coronary artery bypass grafting on the beating heart. This study examines the efficacy and safety of two types of coronary artery stabilizers developed to perform coronary artery bypass grafting on the beating heart. Methods. Four dogs underwent left internal mammary artery to left anterior descending artery anastomosis using a retractor-fixed stabilizer. Measurements of hemodynamic indices and range of motion of the targeted arteriotomy were done before and after application of the stabilizers. Patency of the anastomosis was evaluated by angiography. To clinically validate the safety of this stabilizer, we collected data on 150 patients from centers that had access to the retractor-fixed stabilizer. Results. All animals survived the procedure with no ischemic changes or hemodynamic alterations. A significant reduction in range of motion (mm) of the left anterior descending coronary artery was achieved after application of the stabilizers. Angiographic studies showed good anastomotic patency. Histologic examination showed no myocardial injury. Patient data revealed successful completion of the anastomosis, with conversion to sternotomy or cardiopulmonary bypass in 1 patient each. Intraoperative and postoperative myocardial infarctions occurred in 1 patient each, with one in-hospital death. Conclusions. Significant stabilization of targeted coronary arteries allowing the performance of safe and reliable anastomosis on a beating heart can be achieved using the stabilizer. (C) 1997 by The Society of Thoracic Surgeons.
引用
收藏
页码:988 / 992
页数:5
相关论文
共 21 条
[1]   TO USE OR NOT TO USE PUMP OXYGENATOR IN CORONARY-BYPASS OPERATIONS [J].
ANKENEY, JL .
ANNALS OF THORACIC SURGERY, 1975, 19 (01) :108-109
[2]   COGNITIVE FUNCTION AFTER OPEN-HEART-SURGERY - ARE POSTOPERATIVE NEUROPSYCHOLOGICAL DEFICITS CAUSED BY CARDIOPULMONARY BYPASS [J].
BENEDICT, RHB .
NEUROPSYCHOLOGY REVIEW, 1994, 4 (03) :223-255
[3]  
BENETTI FJ, 1991, J THORAC CARDIOV SUR, V102, P802
[4]  
BENETTI FJ, 1985, J CARDIOVASC SURG, V26, P217
[5]   DIRECT MYOCARDIAL REVASCULARIZATION WITHOUT EXTRACORPOREAL-CIRCULATION - EXPERIENCE IN 700 PATIENTS [J].
BENETTI, FJ ;
NASELLI, G ;
WOOD, M ;
GEFFNER, L .
CHEST, 1991, 100 (02) :312-316
[6]   Coronary artery bypass grafting without cardiopulmonary bypass [J].
Buffolo, E ;
deAndrade, JCS ;
Branco, JNR ;
Teles, CA ;
Aguiar, LF ;
Gomes, WJ .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :63-66
[7]   RELEASE OF VASOACTIVE SUBSTANCES DURING CARDIOPULMONARY BYPASS [J].
DOWNING, SW ;
EDMUNDS, LH .
ANNALS OF THORACIC SURGERY, 1992, 54 (06) :1236-1243
[8]  
DUBOST A, 1990, ARCH MAL COEUR VAISS, V83, P947
[9]   MYOCARDIAL NEUTROPHIL SEQUESTRATION AND ACTIVATION RELATED TO THE REPERFUSION OF HUMAN HEART DURING CORONARY-ARTERY SURGERY [J].
FARAH, B ;
VUILLEMENOT, A ;
LECOMPTE, T ;
BARA, L ;
PASQUIER, C ;
JEBARA, V ;
CARPENTIER, A ;
FABIANI, JN .
CARDIOVASCULAR RESEARCH, 1994, 28 (08) :1226-1230
[10]   FUTURE-DEVELOPMENTS IN HIGH-TECHNOLOGY ABDOMINAL-SURGERY - ULTRASOUND, STEREO IMAGING, ROBOTICS [J].
GOH, P ;
TEKANT, Y ;
KRISHNAN, SM .
BAILLIERES CLINICAL GASTROENTEROLOGY, 1993, 7 (04) :961-987