The accuracy of the central landmark used for central venous catheterization of the internal jugular vein

被引:26
作者
Bailey, PL [1 ]
Whitaker, EE [1 ]
Palmer, LS [1 ]
Glance, LG [1 ]
机构
[1] Univ Rochester, Dept Anesthesiol, Rochester, NY 14642 USA
关键词
D O I
10.1213/01.ane.0000202467.10465.12
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We simulated needle paths based on the central landmark used for central venous catheterization of the internal jugular vein. We obtained ultrasound images to quantify the landmark's accuracy (precision and bias) in 707 subjects placed in Trendelenburg position with their heads turned 30-35 degrees. We also determined the frequency of simulated carotid artery puncture. The simulated needle path missed the middle 80% of the lumen of the internal jugular vein in 34% of subjects (95% confidence interval [CI], 25% to 44%) and traversed the carotid artery in 26% of subjects (95% CI, 18% to 35%). Both events occurred in 20% of subjects (95% CI, 13%-29%). The landmark had a medial bias of 3.7 mm (95% CI, 2.7 to 4.8); it was more often (77 of 104 subjects) medial to the center of the right internal jugular vein (P < 0.001). The landmark was more likely to miss the internal jugular vein (odds ratio, 3.11; P < 0.016) and intersect the carotid (odds ratio, 3.03; P < 0.024) in obese patients. The central landmark should not be expected to yield frequent success on first needle pass without risk of carotid puncture because of its imprecision and bias. The measured bias should be considered when the central landmark is used for central venous catheterization.
引用
收藏
页码:1327 / 1332
页数:6
相关论文
共 28 条
[1]   THE EFFECT OF POSITION AND DIFFERENT MANEUVERS ON INTERNAL JUGULAR-VEIN DIAMETER SIZE [J].
ARMSTRONG, PJ ;
SUTHERLAND, R ;
SCOTT, DHT .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1994, 38 (03) :229-231
[2]   The accuracy of the central landmark used for central venous catheterization of the internal jugular vein [J].
Bailey, PL ;
Whitaker, EE ;
Palmer, LS ;
Glance, LG .
ANESTHESIA AND ANALGESIA, 2006, 102 (05) :1327-1332
[3]   ULTRASONOGRAPHIC ANATOMY OF THE INTERNAL JUGULAR VEIN RELEVANT TO PERCUTANEOUS CANNULATION [J].
BAZARAL, M ;
HARLAN, S .
CRITICAL CARE MEDICINE, 1981, 9 (04) :307-310
[4]   Percutaneous central venous catheterization with a lethal complication [J].
Benter, T ;
Teichgräber, UKM ;
Klühs, L ;
Dörken, B .
INTENSIVE CARE MEDICINE, 1999, 25 (10) :1180-1182
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Pericardiocentesis guided by two-dimensional echocardiography [J].
Callahan, JA ;
Seward, JB .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1997, 14 (05) :497-504
[7]   ULTRASOUND-ASSISTED CANNULATION OF THE INTERNAL JUGULAR-VEIN - A PROSPECTIVE COMPARISON TO THE EXTERNAL LANDMARK-GUIDED TECHNIQUE [J].
DENYS, BG ;
URETSKY, BF ;
REDDY, PS .
CIRCULATION, 1993, 87 (05) :1557-1562
[8]   ANATOMICAL VARIATIONS OF INTERNAL JUGULAR-VEIN LOCATION - IMPACT ON CENTRAL VENOUS ACCESS [J].
DENYS, BG .
CRITICAL CARE MEDICINE, 1991, 19 (12) :1516-1519
[9]   Injuries and liability related to central vascular catheters - A closed claims analysis [J].
Domino, KB ;
Bowdle, TA ;
Posner, KL ;
Spitellie, PH ;
Lee, LA ;
Cheney, FW .
ANESTHESIOLOGY, 2004, 100 (06) :1411-1418
[10]   CASE 1--1996 - Inadvertent carotid artery cannulation during pulmonary artery catheter insertion [J].
Eckhardt, WF ;
Laconetti, DJ ;
Kwon, JS ;
Brown, E ;
Troianos, CA .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (02) :283-290