Localization of prostate cancer using 3T MRI - Comparison of T2-weighted and dynamic contrast-enhanced imaging

被引:98
作者
Kim, CK
Park, BK
Kim, B
机构
[1] Sungkyunkwan Univ Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
[2] Sungkyunkwan Univ Sch Med, Samsung Med Ctr, Ctr Imaging Sci, Seoul 135710, South Korea
关键词
prostate neoplasm; magnetic resonance; tissue characterization; contrast enhancement;
D O I
10.1097/01.rct.0000185384.27765.09
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare dynamic contrast-enhanced imaging and T2-weighted imaging using a 3T MR unit for the localization of prostate cancer. Methods: Twenty consecutive patients with biopsy-proven prostate cancer underwent both T2-weighted imaging and dynamic contrast-enhanced imaging. At T2-weighted imaging and dynamic contrast-enhanced imaging, the presence or absence of prostate cancer confined within the prostate without extracapsular or adjacent organ invasion was evaluated in the peripheral zones of base, mid-gland, and apex on each side. Final decisions on prostate cancer localization were made by consensus between two radiologists. Degrees of depiction of tumor borders were graded as poor, fair, or excellent. Results: Prostate cancer was pathologically detected in 64 (53%) of 120 peripheral zone areas. The sensitivity, specificity, and accuracy for prostate cancer detection were 55%, 88% and 70% for T2-weighted imaging and 73%, 77%, and 75% for dynamic contrast-enhanced imaging, respectively. Three cancer areas were detected only by T2-weighted imaging, 15 only by dynamic contrast- enhanced imaging, and 34 by both T2-weighted imaging and dynamic contrast-enhanced imaging. A fair or excellent degree at depicting turner border was achieved in 67% by T2-weighted imaging and in 90% by dynamic contrast-enhanced imaging (P < 0.05). Conclusions: Dynamic contrast-enhanced imaging at 3T MRI is superior to T2-weighted imaging for the detection and depiction of prostate cancer and thus is likely to be more useful for preoperative staging.
引用
收藏
页码:7 / 11
页数:5
相关论文
共 22 条
  • [1] THE ROLE OF INTRAVENOUS CONTRAST ENHANCEMENT IN MAGNETIC-RESONANCE-IMAGING OF PROSTATIC-CARCINOMA
    BROWN, G
    MACVICAR, DA
    AYTON, V
    HUSBAND, JE
    [J]. CLINICAL RADIOLOGY, 1995, 50 (09) : 601 - 606
  • [2] Prostate cancer: Evaluation of vascular characteristics with dynamic contrast-enhanced T1-weighted MR imaging - Initial experience
    Buckley, DL
    Roberts, C
    Parker, GJM
    Logue, JP
    Hutchinson, CE
    [J]. RADIOLOGY, 2004, 233 (03) : 709 - 715
  • [3] Extraprostatic spread of clinically localized prostate cancer:: Factors predictive of pT3 tumor and of positive endorectal MR imaging examination results
    Cornud, F
    Flam, T
    Chauveinc, L
    Hamida, K
    Chrétien, Y
    Vieillefond, A
    Hélénon, O
    Moreau, JF
    [J]. RADIOLOGY, 2002, 224 (01) : 203 - 210
  • [4] El-Gabry EA, 2001, ONCOLOGY-NY, V15, P325
  • [5] Discrimination of prostate cancer from normal peripheral zone and central gland tissue by using dynamic contrast-enhanced MR imaging
    Engelbrecht, MR
    Huisman, HJ
    Laheij, RJF
    Jager, GJ
    van Leenders, GJLH
    Hulsbergen-Van De Kaa, CA
    de la Rosette, JJMCH
    Blickman, JG
    Barentsz, JO
    [J]. RADIOLOGY, 2003, 229 (01) : 248 - 254
  • [6] Local staging of prostate cancer using magnetic resonance imaging: a meta-analysis
    Engelbrecht, MR
    Jager, GJ
    Laheij, RJ
    Verbeek, ALM
    van Lier, HJ
    Barentsz, JO
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (09) : 2294 - 2302
  • [7] Fütterer JJ, 2004, INVEST RADIOL, V39, P671
  • [8] CARCINOMA OF THE PROSTATE-GLAND - MR-IMAGING WITH PELVIC PHASED-ARRAY COILS VERSUS INTEGRATED ENDORECTAL PELVIC PHASED-ARRAY COILS
    HRICAK, H
    WHITE, S
    VIGNERON, D
    KURHANEWICZ, J
    KOSCO, A
    LEVIN, D
    WEISS, J
    NARAYAN, P
    CARROLL, PR
    [J]. RADIOLOGY, 1994, 193 (03) : 703 - 709
  • [9] Dynamic TurboFLASH subtraction technique for contrast-enhanced MR imaging of the prostate: Correlation with histopathologic results
    Jager, GJ
    Ruijter, ETG
    vanderKaa, CA
    delaRosette, JJMCH
    Oosterhof, GON
    Thornbury, JR
    Ruijs, SHJ
    Barentsz, JO
    [J]. RADIOLOGY, 1997, 203 (03) : 645 - 652
  • [10] In vivo prostate magnetic resonance imaging and magnetic resonance spectroscopy at 3 Tesla using a transceive pelvic phased array coil - Preliminary results
    Kim, HW
    Buckley, DL
    Peterson, DM
    Duensing, GR
    Caserta, J
    Fitzsimmons, J
    Blackband, SJ
    [J]. INVESTIGATIVE RADIOLOGY, 2003, 38 (07) : 443 - 451