Comparison of cardiac output and circulatory blood volumes by transpulmonary thermo-dye dilution and transcutaneous indocyanine green measurement in critically ill patients

被引:48
作者
Sakka, SG
Reinhart, K
Wegscheider, K
Meier-Hellmann, A
机构
[1] Univ Jena, Dept Anesthesiol & Intens Care Med, D-07740 Jena, Germany
[2] Univ Hamburg, Dept Stat & Econometry, D-20246 Hamburg, Germany
关键词
cardiac output; circulatory volumes; critically ill patients; indocyanine green; thermodilution;
D O I
10.1378/chest.121.2.559
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: We prospectively studied the agreement between transpulmonary aortic fiberoptic-based and pulse dye densitometry (PDD) measurements of cardiae output and circulatory blood volumes. Design: Prospective clinical study. Setting: Operative ICU of a university hospital. Patients: Sixteen critically ill, deeply sedated patients receiving mechanical ventilation with ARDS (n = 8), sepsis/septic shock (n = 6), subarachnoid hemorrhage (n = 1), and severe head injury (n = 1). Measurements and results. Each patient received a 4F aortic catheter with an integrated fiberoptic and thermistor that was connected to a computer system for automatic calculation of the transpulmonary indicator dilution (TTID) technique for the measurement of cardiac output (COTPID), intrathoracic blood volume, (ITBV), and total blood volume measured by TPID technique (TBVTPID). In each patient, an indocyanine green sensor was attached to one nasal wing and connected to an analyzer for the PDD measurement of cardiac output (COPDD), central blood volume (CBV), and TBV measured by PDD (TBVPDD). For all first measurements, linear regression analysis between COTPID and COPDD revealed that COPDD = 0.63 x COTPID + 3.69 (L-min) [r = 0.64, p = 0.008]. Mean bias between both techniques was - 0.8 L/min (SD, 1.7 L/min). Correlations between ITBV/CBV (r = 0.52) and TBVTPID/TBVPDD were only moderate; TBVPDD = 0.74 x TBVTPID + 2,362 (mL) [r = 0.60, p = 0.015; mean bias, - 999 mL; SD, 1,353 mL]. Over all 55 measurements, TPID measurements were on average 11.5% (cardiac output) and 17.6% (TBV) higher than PDD measurements. The differences between both measurements ranged from - 58 to 81% (cardiac output) and from - 47 to 82% (TBV; 95% reference ranges). The main source of variation were the intraindividual differences, resulting in different peaks and trends in the patients' time courses depending on which measurement method was used. Conclusion. PDD measurement of cardiae output and circulatory blood volumes agrees moderately with transpulmonary thermo-dye dilution technique in critically ill patients.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 27 条
[1]   Blood volume measurement - The next intraoperative monitor? [J].
Barker, SJ .
ANESTHESIOLOGY, 1998, 89 (06) :1310-1312
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   CARDIAC-OUTPUT MEASUREMENT USING FEMORAL-ARTERY THERMODILUTION IN PATIENTS [J].
BOCK, JC ;
BARKER, BC ;
MACKERSIE, RC ;
TRANBAUGH, RF ;
LEWIS, FR .
JOURNAL OF CRITICAL CARE, 1989, 4 (02) :106-111
[4]   Effects of continuous negative extrathoracic pressure versus positive end-expiratory pressure in acute lung injury patients [J].
Borelli, M ;
Benini, A ;
Denkewitz, T ;
Acciaro, C ;
Foti, G ;
Pesenti, A .
CRITICAL CARE MEDICINE, 1998, 26 (06) :1025-1031
[5]   NEW TECHNIQUE FOR MEASUREMENT OF CARDIAC OUTPUT BY THERMODILUTION IN MAN [J].
GANZ, W ;
DONOSO, R ;
MARCUS, HS ;
FORRESTER, JS ;
SWAN, HJC .
AMERICAN JOURNAL OF CARDIOLOGY, 1971, 27 (04) :392-+
[6]   Reproducibility of double indicator dilution measurements of intrathoracic blood volume compartments, extravascular lung water, and liver function [J].
Godje, O ;
Peyerl, M ;
Seebauer, T ;
Dewald, O ;
Reichart, B .
CHEST, 1998, 113 (04) :1070-1077
[7]   Central venous pressure, pulmonary capillary wedge pressure and intrathoracic blood volumes as preload indicators in cardiac surgery patients [J].
Godje, O ;
Peyerl, M ;
Seebauer, T ;
Lamm, P ;
Mair, H ;
Reichart, B .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 13 (05) :533-539
[8]   Measurement of blood volume using indocyanine green measured with pulse-spectrophotometry: Its reproducibility and reliability [J].
He, YL ;
Tanigami, H ;
Ueyama, H ;
Mashimo, T ;
Yoshiya, I .
CRITICAL CARE MEDICINE, 1998, 26 (08) :1446-1451
[9]   BEDSIDE ASSESSMENT OF INTRAVASCULAR VOLUME STATUS IN PATIENTS UNDERGOING CORONARY-BYPASS SURGERY [J].
HOEFT, A ;
SCHORN, B ;
WEYLAND, A ;
SCHOLZ, M ;
BUHRE, W ;
STEPANEK, E ;
ALLEN, SJ ;
SONNTAG, H .
ANESTHESIOLOGY, 1994, 81 (01) :76-86
[10]   Cardiac output and circulating blood volume analysis by pulse dye-densitometry [J].
Iijima, T ;
Aoyagi, T ;
Iwao, Y ;
Masuda, J ;
Fuse, M ;
Kobayashi, N ;
Sankawa, H .
JOURNAL OF CLINICAL MONITORING, 1997, 13 (02) :81-89