Flow injection microbial trichloroethylene sensor

被引:36
作者
Han, TS
Sasaki, S
Yano, K
Ikebukuro, K
Kitayama, A
Nagamune, T
Karube, I
机构
[1] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
[2] Univ Tokyo, Grad Sch Engn, Dept Chem & Biotechnol, Bunkyo Ku, Tokyo 1130033, Japan
关键词
trichloroethylene; ion selective electrode; flow injection analysis;
D O I
10.1016/S0039-9140(02)00027-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow type microbial biosensor for direct measurement of trichloroethylene (TCE) was developed. The unique features of this novel microbial sensor were the use of the TCE degrading bacterium Pseudomonas aeruginosa JI104, the electrical detection of the chloride ion released by microbial degradation, and flow cell made of glass. Glass cell was used in order to suppress adsorption of TCE and made a closed reaction cell. Vaporization of TCE during the measurement was prevented using closed flow cell. The performance of the sensor was evaluated from following aspects; such as pH of the carrier solution, amount of the immobilized microbe, flow rate and injection volume. The sensor signals were linearly proportional to the concentration of TCE in the range from 0.03 to 2 mg l(-1), which is suitable for the determination of suspected samples to be drinkable water or not. The sensor performance was checked on the real sample, and this system showed good response in ground water, indicating its applicability for the on line monitoring at TCE contaminated areas or hazardous sites. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 25 条
[1]   KINETICS OF THE DEPLETION OF TRICHLOROETHENE [J].
BARRIOLAGE, G ;
PARSONS, FZ ;
NASSAR, RS .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1987, 21 (04) :366-370
[2]  
*COUNC NAT RES, 1994, ALT GROUND WAT CLEAN
[3]   Sewer and tank flushing for sediment, corrosion, and pollution control [J].
Fan, CY ;
Field, R ;
Pisano, WC ;
Barsanti, J ;
Joyce, JJ ;
Sorenson, H .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 2001, 127 (03) :194-201
[4]  
Garg A, 2001, INDIAN J CHEM TECHN, V8, P219
[5]   Microbial sensor for trichloroethylene determination [J].
Han, TS ;
Kim, YC ;
Sasaki, S ;
Yano, K ;
Ikebukuro, K ;
Kitayama, A ;
Nagamune, T ;
Karube, I .
ANALYTICA CHIMICA ACTA, 2001, 431 (02) :225-230
[6]  
KIMABARA K, 1988, AGR BIOL CHEM TOKYO, V52, P2885
[8]  
KITAYAMA A, 1997, THESIS U TOKYO
[9]   A NOVEL MICROBIAL SENSOR FOR THE DETERMINATION OF CYANIDE [J].
LEE, JI ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1995, 313 (1-2) :69-74
[10]  
MORIOKA Y, 1996, J JPN SOC WATER ENV, V19, P529