Effect of on-capillary large volume sample stacking on limits of detection in the capillary zone electrophoretic determination of selected drugs, dyes and metal chelates

被引:37
作者
Smyth, WF [1 ]
Harland, GB [1 ]
McClean, S [1 ]
McGrath, G [1 ]
Oxspring, D [1 ]
机构
[1] DOW ELANCO EUROPE,FST DEPT,WANTAGE OX12 9JT,OXON,ENGLAND
关键词
sample stacking; dyes; metal chelates; flurazepam; narcotine; clenbuterol; codeine; pethidine;
D O I
10.1016/S0021-9673(97)00182-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
On-capillary large volume sample stacking (LVSS) with hydrodynamic injections of up to 240 s can be used to significantly decrease the limits of detection (LODs) of selected cationic basic drugs, such as clenbuterol, narcotine, flurazepam, codeine and pethidine, by capillary zone electrophoresis (CZE) by up to two orders of magnitude. This technique for these cations requires the use of the electroosmotic flow (EOF) modifier, cetyltrimethylammonium bromide (CTAB), employed at a concentration of 0.002 mol l(-1) in a run buffer of 0.05 mol l(-1) disodium tetraborate adjusted to pH 2.2 with orthophosphoric acid. In addition, polarity switching has to be employed after stacking and sample solvent removal in order to effect migration to the UV detector set at 210 nm. Similarily, but using visible detection and a run buffer of 0.05 mol l(-1) sodium acetate, 0.002 mol l(-1) CTAB and 1.0.10(-7) mol l(-1) of chelating agent 2-(5'-bromo-2-pyridylazo)-5-diethylamino phenol (5-Br-PADAP) at pH 8, cobalt may be determined as its cationic chelate by LVSS. An LOD of 5.10(-8) mol l(-1) cobalt can be achieved. Anionic species, such as dyes containing SO3- groups, can also be subjected to LVSS using the EOF modifier, diethylenetriamine (DETA) at a concentration of 0.006 mol l(-1) in a run electrolyte of 0.05 mol l(-1) citric acid (pH 2.23). Using a 30 s hydrodynamic injection and reversed polarity CZE without post-stacking polarity switching, LODs can be decreased by up to 20 times. The anionic chelate of boron with the ligand Azomethine H can be subjected to LVSS using the same EOF modifier and run electrolyte. A decrease in LOD is again found, down to a value of 5.10(-8) mol l(-1). This method can be applied to the selective determination of boron at realistic concentrations in an artificial river water matrix containing some 20 trace metal ions.
引用
收藏
页码:161 / 169
页数:9
相关论文
共 14 条
[1]   LARGE-VOLUME STACKING OF ANIONS IN CAPILLARY ELECTROPHORESIS USING AN ELECTROOSMOTIC FLOW MODIFIER AS A PUMP [J].
BURGI, DS .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3726-3729
[2]  
BURGI DS, 1992, ANAL BIOCHEM, V16, P2161
[3]   SAMPLE STACKING OF AN EXTREMELY LARGE INJECTION VOLUME IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1046-1050
[4]   FIELD-AMPLIFIED POLARITY-SWITCHING SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :153-161
[5]   STUDIES OF THE ACID-BASE EQUILIBRIA OF SOME 7-FLUORO-1,4-BENZODIAZEPINES IN AQUEOUS-SOLUTIONS [J].
GROVES, JA ;
SMYTH, WF .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1979, 35 (06) :603-611
[6]   Large-volume sample stacking of selected drugs of forensic significance by capillary electrophoresis [J].
McGrath, G ;
Smyth, WF .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 681 (01) :125-131
[7]   Study of the capillary zone electrophoretic behaviour of selected drugs, and its comparison with other analytical techniques for their formulation assay [J].
McGrath, G ;
McClean, S ;
OKane, E ;
Smyth, WF ;
Tagliaro, F .
JOURNAL OF CHROMATOGRAPHY A, 1996, 735 (1-2) :237-247
[8]  
MCGRATH GJ, 1996, THESIS U ULSTER
[9]   UV-visible spectrophotometric, adsorptive stripping voltammetric and capillary electrophoretic study of 2-(5'-bromo-2'-pyridylazo)-5-diethylaminophenol and its chelates with selected metal ions: Application to the determination of Co(III) in vitamin B-12 [J].
Oxspring, DA ;
Maxwell, TJ ;
Smyth, WF .
ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) :97-105
[10]   Study of the chelation of boron with Azomethine H by differential pulse polarography, liquid chromatography and capillary electrophoresis and its analytical applications [J].
Oxspring, DA ;
McClean, S ;
OKane, E ;
Smyth, WF .
ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) :295-301