A new sample-processing unit for the fluorescent microsphere method

被引:48
作者
Raab, S [1 ]
Thein, E [1 ]
Harris, AG [1 ]
Messmer, K [1 ]
机构
[1] Univ Munich, Inst Surg Res, D-81366 Munich, Germany
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1999年 / 276卷 / 05期
关键词
filtration; reference blood sample; organ digestion; blood flow measurement; instrumentation;
D O I
10.1152/ajpheart.1999.276.5.H1801
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of fluorescent-labeled microspheres (FM) for measurement of regional blood flow is an attractive alternative to the use of radioactive-labeled microspheres. In the FM method the FM have to be completely recovered from the tissue samples in a time- and labor-intensive process. For this reason, a considerable loss of FM is possible. The aim Of this study was to develop a filtration device that allows the tissue sample to remain in a single container throughout the procedure to make the process easier and to avoid the loss of FM. The core of the sample-processing unit (SPU) is a single-tube filtration device with a polyamide wire mesh. The protocol for processing tissue from different organs (heart, kidney, liver, spleen, intestine, muscle, bone, lung, brain) was modified and thus shortened significantly. Furthermore, the SPU allows direct filtration of the blood reference sample without previous digestion. Different experiments showed that the SPU in combination with the new protocol excludes the loss of 15-mu m FM. The modifications of the whole procedure render it faster and highly standardized.
引用
收藏
页码:H1801 / H1806
页数:6
相关论文
共 6 条
[1]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[2]   VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION [J].
GLENNY, RW ;
BERNARD, S ;
BRINKLEY, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) :2585-2597
[3]   DEVELOPMENTS IN NONRADIOACTIVE MICROSPHERE TECHNIQUES FOR BLOOD-FLOW MEASUREMENT [J].
PRINZEN, FW ;
GLENNY, RW .
CARDIOVASCULAR RESEARCH, 1994, 28 (10) :1467-1475
[4]   CIRCULATION OF FETUS IN UTERO - METHODS FOR STUDYING DISTRIBUTION OF BLOOD FLOW CARDIAC OUTPUT AND ORGAN BLOOD FLOW [J].
RUDOLPH, AM ;
HEYMANN, MA .
CIRCULATION RESEARCH, 1967, 21 (02) :163-&
[5]   MIC-II - PROGRAM FOR DETERMINATION OF CARDIAC-OUTPUT, ARTERIOVENOUS SHUNT AND REGIONAL BLOOD-FLOW USING RADIOACTIVE MICROSPHERE METHOD [J].
SCHOSSER, R ;
ARFORS, KE ;
MESSMER, K .
COMPUTER PROGRAMS IN BIOMEDICINE, 1979, 9 (01) :19-38
[6]   FLUORESCENT MICROSPHERES TO MEASURE ORGAN PERFUSION - VALIDATION OF A SIMPLIFIED SAMPLE PROCESSING TECHNIQUE [J].
VANOOSTERHOUT, NFM ;
WILLIGERS, HMM ;
RENEMAN, RS ;
PRINZEN, FW .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (02) :H725-H733